# CCTV no picture or image

> CCTV with no picture or a black screen in Eastleigh: what causes it, what to check safely and how the camera, cable and recorder are tested on a visit.

A CCTV camera shows no picture when it loses power, its cable fails or the recorder stops showing it. MCI Electrical tests each in turn and tells you which part has failed.

## Why does my CCTV camera show no picture?

A blank view means the picture is stopping somewhere between the camera lens and the screen you watch. Five faults account for most black screens.
- **The camera has lost power:** A failed power adaptor, a loose low voltage connector or a tripped supply leaves the camera dead. Look for the small status light, or the red glow of the infrared lamps at night.
- **The video cable is damaged:** Coax or network cable can be crushed, cut by a drill, chewed or corroded at a joint. The camera stays powered but the recorder receives nothing from it.
- **Water has got into the camera:** A perished seal or an open cable entry lets moisture into the housing. The picture goes foggy first, then fades to black, and a wet camera that is still powered can short out.
- **The lens, sensor or night lamps have failed:** A camera can power up and send a dark or smeared image when its sensor is worn out. Failed infrared lamps leave the night view black while the day view looks normal.
- **The recorder or monitor is set wrong:** A monitor on the wrong input shows black although every camera is working. A recorder that has reset after a power cut can also lose its camera channels.

## What can I check safely when CCTV has no picture?

Stay with what you can see and reach without opening any equipment or touching mains wiring. These checks sort a screen setting from a real fault.
- **Count the blank cameras:** Flick through every view on the recorder. One blank view points to that camera or its cable, while every view blank points to the recorder, the monitor or a shared power supply.
- **Choose the right monitor input:** Use the monitor's own remote or buttons to select the input the recorder is plugged into. Do not take the cover off the monitor or pull its power lead.
- **Look at the plugs you can reach:** Check that the video lead and the power lead sit fully home at the recorder and monitor. Leave any cable with cracked insulation, bare metal, scorch marks or damp alone.
- **Watch the camera at dusk:** A camera with no status light and no infrared glow after dark has no power. If you can see water inside the housing, do not touch it and keep clear until it is tested.

## When should I book an electrician for a CCTV black screen?

Book when the safe checks have not brought the picture back, or when the fault sits in fixed wiring, at height or in a wall.
- **Every camera is blank:** Several cameras failing together points to the recorder, a shared power supply or a main cable run, and each of those needs testing with meters rather than guessing.
- **One camera stays blank:** A single dead view with the cables seated needs the power at that camera and the cable back to the recorder tested, so the camera is not replaced when the cable is the fault.
- **The fault is out of reach:** A hardwired supply, cable running inside walls or underground, or a camera mounted high on a gable or gantry needs an electrician with the right access equipment.
- **There is damage or water:** A hanging camera, split cable, loose outdoor fitting or any water around live equipment needs to be made safe before the system is switched back on.

## What happens when MCI Electrical visits a CCTV fault?

The visit follows the picture backwards from the screen to the camera, so the fault is pinned to one part before anything is replaced.
- **Screen and recorder first:** We check the monitor input, the recorder display and each camera channel to see whether the system is receiving any picture at all.
- **Power tested at the camera:** We measure the supply reaching the affected camera and its power unit, which tells us at once whether the camera has power or the feed has failed.
- **Cable and picture signal checked:** We test the video cable between the camera and recorder for breaks and poor joints, and inspect the camera for water, a damaged lens or failed infrared lamps.
- **The fault explained before work:** We tell you which part has failed and what putting it right involves, whether that is a connection, a power unit, a cable or a replacement camera, before any further work starts.

## What does the price for a CCTV fault visit cover?

The price shown covers coming out, testing the power, cable, camera and recorder linked to the missing picture, and finding which part has failed. It changes when the fault needs a replacement camera, power unit, cable repair or recorder, because those depend on what the tests show.
- CCTV installation: from £1,450; £1,450: 4 included (camera); £325 for each additional one.
- Quotes are free, rescheduling is free and there is no callout fee.
- Work outside your trading hours is charged at a different rate, and we tell you what it is before we set off.
- Replacement cameras, power units, cables and recorders are priced once testing shows which part failed.

## CCTV installation near you
- [CCTV installation in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/cctv-installation)
- [CCTV installation in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/cctv-installation)
- [CCTV installation in Whiteley](https://mci-electrical.co.uk/commercial-electrician-whiteley/cctv-installation)

## CCTV no picture questions

### Why has only one of my CCTV cameras gone black?

One blank camera points to that camera, its power supply or the cable back to the recorder, because the recorder and the other views are working. Testing the power and the cable separates a dead camera from a damaged lead.

### Should I replace a camera that shows no picture?

Cameras are normally replaced rather than repaired, but a new one will not help if the cable or power unit is the fault. Testing first shows whether the camera needs replacing, and a new camera often works with the recorder you already have.

### Can water damage a CCTV camera?

Yes. Even outdoor cameras let water in when a housing seal perishes or the cable entry is not sealed properly. The picture goes foggy before it fails, and the camera should be left alone until it has been tested.

### Why does my phone app show nothing when the recorder screen works?

The recorder is receiving pictures, so the cameras and cables are fine. The break is in the network link that carries the picture to your phone, such as the router, the internet connection or the recorder's network settings.

## Related problems
- [Why is my CCTV not working?](https://mci-electrical.co.uk/problems/cctv-not-working): A blank camera view or missing footage traces to camera power, the cabling or the recorder, and each part is tested separately on site.
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Circuit breaker won't reset or trip switch won't go back up](https://mci-electrical.co.uk/problems/circuit-breaker-wont-reset): A breaker that springs back means a live fault or a failed device; testing separates the two before anything is repaired.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [HSE: Electrical safety at work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-20.

[CCTV installation](https://mci-electrical.co.uk/services/cctv-installation)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)