title: "Circuit breaker keeps tripping | NICEIC · From £65 an hour"
description: "Circuit breaker keeps tripping at your Eastleigh premises: the usual causes, what is safe to check and how MCI Electrical finds the fault."
canonical: "https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping"
---

# Circuit breaker keeps tripping

> Circuit breaker keeps tripping at your Eastleigh premises: the usual causes, what is safe to check and how MCI Electrical finds the fault.

A circuit breaker keeps tripping when its circuit carries too much load or has a fault such as a short circuit or loose connection. MCI Electrical traces which one it is at business premises in Eastleigh.

## Why does my circuit breaker keep tripping?

A circuit breaker cuts the power to one circuit when it carries more current than it is rated for or when a fault lets current take the wrong path.
- **Too much load on one circuit:** Heaters, kettles, a microwave and a printer on the same circuit can add up to more than the breaker allows. It trips after a while rather than at once, usually at busy times of day.
- **A short circuit in the cable:** Damaged insulation lets live and neutral conductors touch. The current surges and the breaker trips the moment it is switched back on.
- **A faulty item plugged in:** A failing heater, fan, charger or tool can short inside its casing. The circuit is sound, but the breaker trips whenever that item is switched on.
- **A loose connection:** A terminal that has worked loose at a socket, junction box or the breaker itself heats up and can arc. That is a spark jumping across the gap, and it trips the breaker or leaves a burnt smell.
- **The wrong size of breaker:** A breaker rated too low for the load, perhaps after an extra socket or machine was added, trips under normal use. Fitting a bigger one is not the answer, because the cable has to carry the current.
- **A worn breaker:** Breakers can weaken with age and many trips. One that trips below its rating, or will not stay reset, needs testing and often replacing.

## What can I check safely when a circuit breaker keeps tripping?

You can find the breaker, unplug items and reset it once without opening the board or touching any wiring.
- **Find the tripped breaker:** Look at the distribution board, the metal box of breakers, with its cover shut. The one that tripped sits differently from the rest. Note which lights, sockets and machines have gone off.
- **Unplug everything on that circuit:** Remove plugs from the dead sockets, including heaters, chargers and kitchen items. Then switch the breaker back on once. If it stays on, the fault is in something you unplugged.
- **Plug items back in one at a time:** Reconnect each item separately, leaving a minute between them. The one that trips the breaker has the fault, or the combined load is too high. Leave that item unplugged.
- **Leave the breaker alone if it trips empty:** If it trips with nothing plugged in, or straight away on reset, stop. That points to the fixed wiring, which needs testing, not more resets.

## When should I book an electrician for a circuit breaker that keeps tripping?

Book Now when the breaker trips with nothing plugged in, trips immediately on reset or keeps coming back.
- **It trips with nothing plugged in:** The fault is then in the fixed wiring or the breaker itself, and the circuit needs testing before it is used again.
- **It trips the moment you reset it:** An instant trip usually means a short circuit. Leave the breaker off rather than forcing it, and have the circuit traced.
- **There is heat, buzzing or a burning smell:** Warmth at the board, a hum or a burnt smell points to a loose connection that is arcing. Keep the circuit off and book.
- **The same breaker trips week after week:** A repeated trip on the same circuit means the cause is still there, even when resetting gets things going again. Tracing it costs less than the downtime it causes.

## What happens on a visit for a circuit breaker that keeps tripping?

We start by asking which breaker trips, when it trips and what was running, then test that circuit from the board outwards.
- **Isolate and test for faults:** We switch the circuit off and prove it dead. An insulation resistance test then checks for a short circuit or a leak to earth along the cable.
- **Check the load and the connections:** We work out what the circuit feeds and whether it is overloaded, then inspect the connections on it for looseness or signs of overheating.
- **Test the breaker itself:** A breaker can fail while the wiring is fine. We test that it trips at its rated current and replace it if it does not.
- **Repair and write it up:** We fix the loose connection, damaged cable or faulty feed once you say go ahead, test the circuit again and leave a written note of the cause and the readings.

## What does fixing a tripping circuit breaker cost and what changes it?

The hourly rate for commercial fault finding pays for attendance and the time spent testing the circuit until the cause is found. What you pay changes with how long the trace takes, the parts needed and when the visit takes place.
- Commercial fault finding and repair: from £75 an hour
- Tall poles, metal roofs, listed brickwork and extra indoor points change the price after we have seen the building.
- A new breaker or a replacement distribution board is quoted separately from the fault finding time.
- Splitting an overloaded circuit into two is new work and is priced once we know what it involves.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Common questions about a breaker that keeps cutting out

### Can I fit a bigger breaker to stop it tripping?

No. A breaker is sized to protect the cable on its circuit, so a larger one lets the cable overheat before it trips. We find why it trips and fix that instead.

### Why does my breaker trip when two heaters run together?

Yes. Starlink sells you the kit and posts it to you, then we fit it on arrival. Because you buy it directly, the warranty and the monthly airtime stay with your own account.

### How is a breaker different from a fuse?

Yes. Shops, offices and yards are regular places for a dish. We pick fixings to match the roof covering, and a metal roof or a tall pole gets its price once we have seen the building.

### Will you switch off the whole building to test one breaker?

Only when the new socket, spur or circuit calls for one, and then we issue it as NICEIC work. Pairing the dish and running speed tests are done through Starlink.

## Related problems
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
- [No power in one room of a commercial building](https://mci-electrical.co.uk/problems/no-power-in-one-room): Power stops in one room when the circuit feeding it trips or fails, and testing from the board finds where.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [IET: BS 7671 Guidance Publications](https://electrical.theiet.org/guidance-and-codes-of-practice/publications-by-category/bs-7671-and-guidance/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)