# Circuit breaker won't reset or trip switch won't go back up

> Circuit breaker won't reset at an Eastleigh business? Why it happens, what to check safely and how MCI Electrical tests the circuit to find the fault.

A breaker that springs back down means a fault is still live on the circuit or the switch has worn out. At commercial premises in Eastleigh, MCI Electrical tests the circuit to tell which.

## Why won't a circuit breaker reset?

A breaker that will not stay on is reacting to a fault it still senses, or its own latch has worn out. Either way the cause sits on the circuit or inside the device.
- **A short circuit on the circuit:** A live conductor touching neutral or earth makes the breaker spring back the moment it is switched on. Crushed cable and a loose strand at a terminal are common ways it happens.
- **Leakage to earth:** Damp or damaged insulation lets current escape to earth. The leak is small until the breaker is reset, then the protection operates again at once.
- **Water in wiring or fittings:** Water in a socket, outside light or junction box shorts the circuit behind it. It keeps tripping until the fitting dries out and the damaged part is dealt with.
- **A failed breaker:** The MCB, short for miniature circuit breaker, can wear until its latch no longer holds. The handle then feels loose and drops back even with the circuit disconnected.
- **Chewed or crushed cable:** Rodents strip insulation in ceiling voids and under floors, and building work can crush a cable. Either leaves a fault that does not clear by itself.

## What can be checked safely when a breaker will not reset?

Look and make notes only. Never hold a breaker on, bypass it or open a board, socket or fitting.
- **Unplug and try once:** Switch off or unplug everything that runs from that circuit, then move the breaker back up one time. If it springs back with nothing connected, leave it off.
- **Note what lost power:** Write down which lights, sockets, tills or machines went dead and what was running when it happened. That tells us which circuit to start on.
- **Look and listen from a distance:** Check for water, scorch marks, a burning smell or buzzing around the board and the dead fittings. Touch nothing damp, and leave the breaker off if you find any of these.

## When should an electrician be booked for a breaker that will not reset?

Book Now when the breaker springs back after one reset with everything unplugged, because that means the fault is still there.
- **It will not latch at all:** A handle that will not stay up even with the circuit disconnected points to a failed breaker. It needs replacing, and forcing it only risks damage.
- **Heat, a smell or visible damage:** A warm board, a burning smell or a scorched fitting can mean an arcing connection. Leave it off and book at once.
- **Something essential is off:** Chillers, alarms, emergency lighting and tills stop when their circuit goes. Mention that when you book so the visit is planned around it.
- **It happens after hours:** Calls are answered at any hour. A visit outside working hours carries its own rate, and you hear it before we set off.

## What happens on a visit for a breaker that will not reset?

We meet whoever is on site, then work outwards from the board to separate a failed breaker from a fault on the circuit.
- **Isolate and prove it dead:** We switch the circuit off and confirm with a test meter that it carries no voltage before any cover comes off, so nobody is at risk while we work.
- **Test the breaker, then the circuit:** With the circuit disconnected we see whether the breaker latches. Insulation resistance tests, which measure leakage between the conductors and earth, and continuity tests then trace the fault along the cable.
- **Replace or repair the failed part:** A worn breaker is replaced. A circuit fault is repaired at the damaged cable, joint or fitting, and larger planned work, such as a whole board change, is quoted separately.
- **Test again and say what is safe:** We test the circuit once more before power returns, then tell you what is safe to use and what needs a return visit. NICEIC paperwork follows where the work needs it.

## What does fixing a breaker that will not reset cost?

An out of hours visit is charged by the hour and covers attendance, finding the fault and the first safe repair. The same fault in working hours is a separate daytime booking with its own hourly rate. Time on site, parts and any follow on repair change the total.
- Emergency callout (out of hours): from £105 an hour
- A single worn breaker takes less time than a fault somewhere along a long cable run.
- Parts and any repair beyond the first safe fix are charged once the cause is known.
- Out of hours work carries a different rate from daytime work, and we tell you the rate before we set off.

## Emergency electrician near you
- [Emergency electrician in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/emergency-callout)
- [Emergency electrician in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/emergency-callout)
- [Emergency electrician in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/emergency-callout)
- [Emergency electrician in Whiteley](https://mci-electrical.co.uk/commercial-electrician-whiteley/emergency-callout)

## Questions about a breaker that will not reset

### Can I hold the breaker on to keep the power?

No. Holding it on defeats the protection that guards against fire and electric shock. Leave it off and have the circuit tested.

### Is the breaker broken or is it a wiring fault?

Testing tells the two apart. A breaker that will not latch with the circuit disconnected has failed itself. One that latches but springs back once the circuit is connected points to a fault in the cable or fittings.

### Could mice or rats have caused it?

Yes. They chew cable insulation under floors and in ceiling voids, which leaves short circuits and earth faults. The damaged cable then needs replacing, and the cause of the damage is worth dealing with too.

### Do you answer calls when a breaker fails at night?

Yes. Calls are answered at any hour, and an out of hours visit is charged at its own rate that you hear before we set off.

## Related problems
- [Half the house has no electricity](https://mci-electrical.co.uk/problems/half-house-no-electricity): Half a building going dark means a tripped switch, a failed circuit or a lost feed, and testing from the board shows which.
- [Neighbours have power but I don't](https://mci-electrical.co.uk/problems/neighbours-have-power-i-dont): A dead supply on one unit points to the board, the meter or the incoming cable, and a voltage reading at the incoming terminals shows which.
- [No power at my business after a storm](https://mci-electrical.co.uk/problems/no-power-after-storm): A storm can cut power outside the building or trip and damage the circuits inside it, and only testing shows which.
- [No power in the whole house](https://mci-electrical.co.uk/problems/no-power-in-house): A whole building with no power is a tripped main switch, a failed consumer unit or a fault on the supply coming in. Here is how to tell which.
- [CCTV no picture or image](https://mci-electrical.co.uk/problems/cctv-no-picture): A CCTV black screen comes from lost power, a damaged cable, a wet camera or a wrong recorder or monitor setting, and each one has its own test.
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-20.

[Emergency electrician](https://mci-electrical.co.uk/services/emergency-callout)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)