# Cooker switch not working

> A dead cooker switch in Eastleigh: MCI Electrical tests breaker, switch and appliance in turn to find where power stops, then repairs the failed part.

When a cooker switch goes dead, the loss sits in the breaker, the switch, the cable behind it or the cooker, and MCI Electrical measures along the circuit until the failed part shows itself.

## What makes a cooker switch go dead?

A cooker draws a heavy load for long stretches, so the parts that carry it wear or loosen, and each failure looks like a switch that clicks but gives no power.
- **Burnt contacts inside the switch:** Every time the switch is flicked under load, a small arc eats the metal faces a little further. In the end they stop meeting, so the lever moves but nothing flows to the cooker.
- **A terminal that has worked loose:** A slack screw lets a cable end sit loose in its clamp, where it heats and blackens. The loose clamp may be in the switch, in the cooker's terminal block or at a joint on the cable between them.
- **A dropped cooker breaker:** A cooker has its own breaker on the board. When that lever falls, the lamp on the wall switch and the cooker's display go dark together, which can pass for a failed switch.
- **A fault inside the cooker:** A shorted element or a damaged internal lead can pull the breaker down the moment the cooker is switched on, even though the wall switch is perfectly sound.

## What can a householder safely check?

Stay on the outside of everything: the breaker lever, the switch plate and what the cooker's display shows. Nothing here needs a screwdriver.
- **Look at the cooker's breaker:** Find the breaker marked for the cooker on the board and see whether its lever has dropped below its neighbours. Raise it a single time, then try the cooker.
- **Watch the switch lamp and the cooker display:** A glowing switch lamp beside a blank cooker display means power reaches the switch and stops there. A dark lamp points to a loss earlier along the circuit.
- **Check the plate for heat:** Look for brown or black staining and sniff for burning, and hold the back of a hand near the plate without touching it. If anything feels warm, press the switch off and leave the breaker down.
- **Stop if the breaker falls again:** A breaker that drops after one reset is reporting a fault. Pushing it up again only heats that fault further, so leave it down.

## When should a householder book an electrician?

Book as soon as one reset fails to bring the cooker back, or when anything about the switch looks or smells scorched.
- **One reset has not worked:** With the breaker up and the switch on, a cooker that still has no power has lost its supply at the switch, a connection or the appliance, and only measuring tells you which.
- **The breaker falls again:** A second trip says current is escaping or overloading somewhere on the circuit. That needs a test with the cooker disconnected, not another reset.
- **The switch is hot or smells burnt:** Switch the cooker off at the wall, leave its breaker down and ring straight away. A burning smell means a connection is cooking behind the plate.

## What happens on the visit?

MCI Electrical works from the board outwards, so each stage rules out one part of the circuit before the next is opened.
- **We ask what you saw:** We ask when the cooker went off, what lit or dropped and whether it has done this before, then look at the breaker, the switch plate and the cooker display.
- **We isolate and measure:** With the circuit isolated, we test at the breaker, at the switch and at the cooker's connection to find the point where the supply stops.
- **We repair the part that failed:** A worn switch or control unit is replaced, and scorched cable ends are cut back and remade. We also check that the cable and breaker suit what the cooker draws.
- **We retest and leave a note:** Earth continuity and insulation resistance are measured before the cooker goes back on. You receive a written note of the cause, the parts fitted and the readings, plus NICEIC paperwork when the work is notifiable.

## What changes the price of a cooker switch repair?

The price covers attendance, isolating the cooker circuit and the testing needed to locate the fault, along with the first stretch of repair time. It rises with the time taken to trace the loss and with whether the existing cable and breaker already suit the cooker.
- Commercial fault finding and repair: from £75 an hour
- Replacement switches, control units and other parts are added to the labour, and the hourly rate is put in writing before a board is opened.
- A cable or breaker too small for the cooker means extra work, which is priced separately and discussed before it begins.
- Quotes and rescheduling carry no charge, and there is no callout fee.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Cooker switch questions

### Do you repair cooker switches in workplace kitchens?

Yes. MCI Electrical works on commercial premises, so a cooker in a staff room, canteen or tenanted unit is treated as a failed circuit and traced from the board. Out of hours attendance is a separate rate, told to you in advance.

### Will my cooker need a new circuit?

Often not. If a worn switch or a heated terminal is the cause, the repair stays on the circuit already there. Only when the cable or breaker is too small for the cooker does a new or upgraded circuit come into it, and that is priced in writing first.

### Does the rest of the building lose power while you work?

Only the cooker circuit is isolated where the board allows. Lighting and sockets on other ways usually stay live, so the kitchen next door and the office upstairs can carry on.

### Do you repair the cooker itself?

The work covers the supply, the switch and the connection to the appliance. If testing shows a fault inside the cooker, such as a failed element, the appliance needs its maker or a repair engineer.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
- [No power in one room of a commercial building](https://mci-electrical.co.uk/problems/no-power-in-one-room): Power stops in one room when the circuit feeding it trips or fails, and testing from the board finds where.

## Sources
- [Electrical Safety First: ovens and grills](https://www.electricalsafetyfirst.org.uk/guidance/product-safety/ovens/)
- [Electrical Safety First: wiring regulations help](https://www.electricalsafetyfirst.org.uk/professional-resources/wiring-regulations/new-rewired-and-similar-installations/)
- [HSE: electrical safety at work](https://www.hse.gov.uk/electricity/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)