# Half the house has no electricity

> Half the house has no electricity in Eastleigh? MCI Electrical tests each circuit, traces the fault and brings the supply back. · Prices from £65 an hour

Half the house without electricity usually means one protective switch has tripped or one group of circuits has failed. MCI Electrical tests each circuit from the board outwards, finds the fault and restores the supply.

## Why has half the house lost its electricity?

Electricity reaches a building through several circuits, each guarded by a switch on the board. When one group fails, the part it feeds goes dark and the rest carries on.
- **A residual current device has tripped:** A residual current device, or RCD, is a switch that cuts power when current leaks to earth. Boards often have two, each guarding a different group of circuits, so one tripping darkens its group.
- **Several circuit breakers have dropped out:** A circuit breaker drops out when its circuit is overloaded. Two or three going together on one side of the board can take that whole side down.
- **An appliance is the real fault:** A failing heater, kettle or charger can trip the switch that guards every circuit sharing its protection, so the dead half is the result and the appliance is the cause.
- **A connection in the board has worked loose:** A terminal that has loosened or scorched can drop a group of circuits, and the supply may come back after a reset and fail again. Only testing finds it.
- **A second board has lost its feed:** Some buildings have a sub board, a smaller board fed from the main one. If that feed fails, everything on the sub board goes dead together.

## What can I safely check when half the house has no power?

Looking and switching are safe. Opening anything is not, so leave every cover, socket and fitting closed.
- **Look for a switch that has moved:** Open the door of the board, where it has one, and look for a switch sitting down or halfway. Take no cover off and touch nothing else.
- **Unplug the dead side:** Pull the plugs of heaters, kettles, chargers and other portable items on the dead side before any reset, because one of them is often what tripped the switch.
- **Reset once and stop:** Push a tripped switch fully down, then up, one time. If it drops again, leave it down, because it is stopping a fault from carrying on.
- **Watch for heat or a burning smell:** Warm sockets, brown marks or a scorched smell mean that outlet stays switched off until it has been tested.

## When should I book an electrician?

Book when one reset does not bring the power back. Calls are answered at any time.
- **The switch will not stay on:** Book when it drops again straight after a reset, or when it will not stay up even with the dead side unplugged.
- **The board looks normal:** Book when every switch is up and half the house is still dead. A loose connection or a lost feed is the likely cause, and only testing locates it.
- **Heat, damp or burning:** Book at once when a smell of burning, a warm board or water near a socket goes with the power loss, and leave that circuit off.

## What happens when we visit?

We start at the board and follow the dead circuits outwards, one test at a time.
- **The dead circuits are switched off and tested:** We switch the affected circuits off at the board and test them there. Where the board allows, the circuits that still work stay on.
- **The fault is traced:** Meter readings show whether current is leaking from a cable and whether the cable is unbroken. Together they point to one connection, device or length of cable.
- **The failed part is repaired and tested again:** Once the rate and any parts are settled with you, we mend or swap the failed part. Every circuit is tested again before it is switched back on.
- **A note of the work is left with you:** Notifiable repairs come with NICEIC paperwork. Smaller jobs come with a short written note naming the cause, the parts fitted and the readings taken.

## What does it cost to find and fix a power loss?

Tracing a power loss is charged by the hour, so the total follows how long the fault takes to find and what has to be replaced. The first hour pays for attending, testing and beginning the repair.
- Emergency callout (out of hours): from £105 an hour
- You get the hourly rate in writing before we touch the board, and parts are added on top of the labour.
- Out of hours emergency callout runs at its own hourly rate, which we give you before we set off.
- Nothing is charged to quote, to move a booking or to attend.

## Emergency electrician near you
- [Emergency electrician in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/emergency-callout)
- [Emergency electrician in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/emergency-callout)
- [Emergency electrician in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/emergency-callout)
- [Emergency electrician in Whiteley](https://mci-electrical.co.uk/commercial-electrician-whiteley/emergency-callout)

## Questions about half the house losing power

### Is half a house without power an emergency?

Not on its own. A switch that will not stay up, a burning smell or a wet board is urgent, so keep that circuit off and call. Calls are answered at any time.

### How many times can I reset a tripped switch?

Once. A switch that drops again is doing its job by shutting a fault off, so leave it down and call us rather than trying again.

### Do I need a new board if half the house trips?

Not necessarily. Testing shows whether the fault sits in the board, a circuit or an appliance. A new board is quoted as its own job only if the results call for one.

### Are you NICEIC registered?

Yes. MCI Electrical is NICEIC registered, so any repair that needs a certificate gets one from us when the work is finished.

## Related problems
- [Circuit breaker won't reset or trip switch won't go back up](https://mci-electrical.co.uk/problems/circuit-breaker-wont-reset): A breaker that springs back means a live fault or a failed device; testing separates the two before anything is repaired.
- [Neighbours have power but I don't](https://mci-electrical.co.uk/problems/neighbours-have-power-i-dont): A dead supply on one unit points to the board, the meter or the incoming cable, and a voltage reading at the incoming terminals shows which.
- [No power at my business after a storm](https://mci-electrical.co.uk/problems/no-power-after-storm): A storm can cut power outside the building or trip and damage the circuits inside it, and only testing shows which.
- [No power in the whole house](https://mci-electrical.co.uk/problems/no-power-in-house): A whole building with no power is a tripped main switch, a failed consumer unit or a fault on the supply coming in. Here is how to tell which.
- [CCTV no picture or image](https://mci-electrical.co.uk/problems/cctv-no-picture): A CCTV black screen comes from lost power, a damaged cable, a wet camera or a wrong recorder or monitor setting, and each one has its own test.
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Energy Networks Association: Power Cut Information](https://www.energynetworks.org/operating-the-networks/power-cuts)

Updated 2026-11-20.

[Emergency electrician](https://mci-electrical.co.uk/services/emergency-callout)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)