# Lights not working but sockets are fine

> Lights not working but sockets fine? MCI Electrical in Eastleigh tests the lighting circuit, finds the failed part and repairs it. · Call 07366 896562

When the lights are out and the sockets still work, the fault sits on the lighting circuit alone. MCI Electrical traces it from the board outwards and puts the lights back on.

## Why do my lights fail when the sockets still work?

Lights and sockets run on separate circuits from the board, so one can fail while the other carries on. These are the usual reasons the lighting side stops.
- **The lighting breaker has switched off:** A breaker is the switch in the board that cuts a circuit when something is wrong. If the lighting one has dropped, every light on it goes dark while the sockets stay live.
- **A fitting has failed:** A burnt lamp holder or a dead driver, the small box that powers an LED, can trip the circuit as it fails. One bad fitting can take the whole run with it.
- **A connection has worked loose:** Lights are joined at ceiling roses, switches and junction boxes. When one connection loosens or overheats, everything beyond it goes out and the rest of the circuit may still work.
- **A cable above the ceiling is damaged:** Cable in a ceiling void or loft can be nicked by other trades, crushed or chewed. A break there cuts off every light downstream while nothing shows in the room.

## What can I safely check when the lights are out?

Safe checks need no tools and no covers off. Stop at the first sign of heat, a burning smell or a buzzing board.
- **Look at the lighting breaker:** Open the board door only if it opens without a tool. If one breaker sits down, push it up once. If it drops again straight away, leave it off.
- **Try the lights one at a time:** Switch every light off, reset the breaker, then switch them on one by one. The light that makes the breaker drop is the one to leave off and tell us about.
- **Swap a lamp in a cool fitting:** With the switch off and the fitting cool, fit a new lamp of the same type. Do not open the fitting itself or touch any wiring behind it.

## When should I book an electrician for dead lights?

Book Now when a reset does not hold, or when a whole room or floor stays dark after a new lamp.
- **The breaker drops again after a reset:** A breaker that keeps dropping is reacting to a real fault on the lighting cable or a fitting. Leave it off and let it be tested.
- **Heat, a buzz or a burning smell:** A warm switch, a hum from the board or a scorched smell points to a failing connection. Switch the lighting breaker off and keep clear until it is checked.
- **The problem began after other work:** If the lights failed soon after building work, a new fitting or a DIY change, the cause is probably in that work. Tell us what was done.

## What happens when MCI Electrical attends dead lights?

We start at the board and follow the lighting circuit out to the dark rooms, then repair the part the tests name.
- **We read the board and the symptoms:** We ask which rooms are dark and what was tried, then read the breakers. Live sockets show the supply into the board is fine.
- **We isolate and test the lighting circuit:** We switch the lighting way off and test the cable with instruments. The readings show a break, a short or a leak to earth.
- **We check each connection along the run:** Switches, roses and junction boxes on the failed run are opened and tested in turn. That shows which fitting or joint has failed.
- **We repair and leave a written note:** We replace the failed part, retest the circuit and leave a note of the cause, the parts used and the test result. NICEIC paperwork follows where the repair needs it.

## How is finding a lighting fault priced?

Fault finding is charged by the hour, because nobody can say in advance how long a break takes to trace. The first hour pays for attending, testing and the first repair we can finish.
- Commercial fault finding and repair: from £75 an hour
- We state the hourly rate before we set off, and there is no callout fee.
- Replacement parts and any later hours are charged on top, and we explain each before it starts.
- Work done out of hours has its own rate, which we tell you beforehand.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Dead lights questions

### Is it dangerous if my lights are off but the sockets work?

It is not an emergency, but a lighting circuit that has failed has a fault that needs finding. Use a torch and take care on stairs. Do not keep resetting a breaker that drops.

### Could it just be the lamps?

If one light is out, yes. If a whole room or floor is dark together, the cause is the circuit, and new lamps will not fix it.

### Can you fix lighting faults in offices and shops?

Yes. Tracing faults on commercial installations is what MCI Electrical does, and the company is NICEIC registered. You deal with us from the first call to the repair.

### Do you charge a callout fee?

No. Fault finding is priced by the hour, and the rate is stated before we set off. Rescheduling a visit is free.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
- [No power in one room of a commercial building](https://mci-electrical.co.uk/problems/no-power-in-one-room): Power stops in one room when the circuit feeding it trips or fails, and testing from the board finds where.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)