If neighbouring units have power and yours does not, the fault sits in your own supply, and MCI Electrical tests it from the meter to the board to find where.

## Why do neighbours have power when I don't?

Your unit has lost its own supply, so an area power cut is unlikely. The cause is usually in the equipment between the street and your lights and sockets.
- **A main switch that has dropped:** The main switch on the distribution board, the box of breakers feeding your circuits, can trip and cut the whole unit while next door stays live.
- **A failed residual current device:** An RCD is the breaker that switches off when current leaks to earth. One that fails or keeps tripping can take a whole board down with it.
- **A meter isolator switched off:** Some meters have an isolating switch beside them. If it has been knocked or turned off, nothing reaches the board even though the supply outside is fine.
- **A fault on the incoming cable or fuse:** The cable from the street and the sealed fuse at the meter belong to the network operator. A fault there cuts one unit and leaves its neighbours on.
- **A burnt connection at the main switch:** The tails are the thick cables joining the meter to the main switch. A loose terminal heats up, burns and stops passing power, often leaving a scorch mark.

## What can I check safely when only my unit is dark?

Each of these checks works with the board cover closed and needs no tools or hands inside the equipment.
- **Look next door:** If neighbouring units and the street lights are dark too, ring 105. That is a network power cut and an electrician cannot fix it.
- **Look at the switches on the board:** Find any switch that has dropped down. Push it back up once. If it drops again, leave it off and do not keep trying.
- **Look at the meter:** Check the display is lit and any isolating switch beside the meter is on. Leave the sealed fuse and every seal alone.
- **Unplug what was running:** Pull the plug on portable equipment that was in use when the power went. A faulty heater or kettle can trip a board and stay faulty afterwards.

## When should I book an electrician?

Book as soon as neighbouring units have power and a look at the board has not brought yours back.
- **A switch that will not stay up:** A main switch or RCD that drops again straight away means a fault is still present. Leave it off and book.
- **A burning smell or a warm board:** Heat, scorch marks or a smell of burning mean a connection is failing. Keep clear of the board and press Book Now.
- **Everything looks normal:** If the switches are up, the meter is lit and you still have no power, the break is somewhere that needs test equipment to find.

## What happens when the electrician comes?

The visit works inward from the meter, so each test rules one more part in or out.
- **Time of loss and a look round:** We take down when the supply went and which units nearby still have power. We then look over the meter and board for burn marks or a casing that feels warm.
- **Voltage at the incoming terminals:** A meter reading at the incoming side of the main switch shows whether power arrives. If none does, the fault lies with the network and you report it on 105 with our findings.
- **Tests along the board:** With power arriving, we test the main switch, each RCD and the tails in turn. A switch that no longer passes current or a terminal that has burnt shows up here.
- **Repair or a safe position:** We remake a loose terminal or change a failed device when the part is on the van. If more is needed, the faulty part stays isolated and we write down the work and the price first.

## How is this repair priced?

The price follows what the tests find. An emergency callout is charged by the hour for attendance, testing and the first repair, and parts are added once the fault is known.
- Emergency callout (out of hours): from £105 an hour
- There is no callout fee, and a booked visit can be moved to another day without charge.
- Work arranged for when your premises are shut costs a different rate, and we tell you what it is before we set off.
- Repairs beyond the first fix are priced item by item, so you choose what to do and when.

## Emergency electrician near you
- [Emergency electrician in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/emergency-callout)
- [Emergency electrician in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/emergency-callout)
- [Emergency electrician in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/emergency-callout)
- [Emergency electrician in Whiteley](https://mci-electrical.co.uk/commercial-electrician-whiteley/emergency-callout)

## Questions about a unit with no power

### Who do I ring when only my unit is dark?

If the street and neighbouring units are dark too, ring 105, the national power cut number. If they have power and you do not, the fault is inside your own supply and needs an electrician.

### Can I replace the main fuse myself?

No. The fuse at the meter is sealed and belongs to the network operator. Breaking the seal is not allowed, so leave it and ring 105 if you think it has blown.

### Why does my main switch keep tripping?

Something on the circuits is drawing too much or leaking current. We test each circuit and each appliance lead to find which one, then repair that part.

### Do you attend power loss at commercial premises?

Yes. MCI Electrical is a commercial and industrial electrical company and NICEIC registered. Calls are answered at any time, and an emergency callout has its own hourly rate.

## Related problems
- [Circuit breaker won't reset or trip switch won't go back up](https://mci-electrical.co.uk/problems/circuit-breaker-wont-reset): A breaker that springs back means a live fault or a failed device; testing separates the two before anything is repaired.
- [Half the house has no electricity](https://mci-electrical.co.uk/problems/half-house-no-electricity): Half a building going dark means a tripped switch, a failed circuit or a lost feed, and testing from the board shows which.
- [No power at my business after a storm](https://mci-electrical.co.uk/problems/no-power-after-storm): A storm can cut power outside the building or trip and damage the circuits inside it, and only testing shows which.
- [No power in the whole house](https://mci-electrical.co.uk/problems/no-power-in-house): A whole building with no power is a tripped main switch, a failed consumer unit or a fault on the supply coming in. Here is how to tell which.
- [CCTV no picture or image](https://mci-electrical.co.uk/problems/cctv-no-picture): A CCTV black screen comes from lost power, a damaged cable, a wet camera or a wrong recorder or monitor setting, and each one has its own test.
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.

## Sources
- [Energy Networks Association: Power Cut Information](https://www.energynetworks.org/operating-the-networks/power-cuts)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-20.

[Emergency electrician](https://mci-electrical.co.uk/services/emergency-callout)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)