# No power in one room of a commercial building

> No power in one room in Eastleigh: why its circuit has failed, what is safe to check, and how MCI Electrical traces and repairs the fault.

When one room loses power while the rest of the building works, the fault sits on that room's circuit. MCI Electrical tests the circuit from the board outwards to find the failed part.

## What makes a single room go dead at work?

Each room hangs off its own circuit, so a fault on that circuit darkens that room alone. The cause is one of a handful of failures, and testing tells them apart.
- **A breaker has tripped:** The switch for the circuit sits on the distribution board, the cabinet that splits the supply into separate circuits. It drops out when the circuit overloads or leaks current to earth, and everything on that circuit goes off together.
- **A loose connection at a socket or switch:** A terminal that has worked loose or scorched at one outlet can cut the supply to every outlet beyond it on the same cable. The board shows nothing wrong while the room stays dead.
- **A joint has failed in a junction box:** Cables meet in junction boxes above ceilings or behind panels. A joint that fails there stops the lights or sockets it feeds, even though every switch on the board looks normal.
- **A cable has been damaged:** A fixing driven through a cable, or a run pinched during building work, can break the circuit or let current leak. The room goes dead from the day the damage happens.
- **Something plugged in has failed:** A faulty heater, kettle or charger can trip the circuit it is plugged into. Unplugging the equipment shows whether the item or the wiring is to blame.

## What can I safely check before booking?

Looking and switching are the only safe checks. Never open a socket, a switch, a light fitting or the board itself, and leave anything that smells of burning alone.
- **Look at the board:** Open the door of the distribution board and look for a switch sitting in the off or middle position. Take no covers off.
- **Reset it once:** Push that switch fully off, then on, one time only. If it drops out again, leave it off, because a breaker that keeps tripping is shutting the circuit down to stop a fault.
- **Unplug the room:** Unplug everything from that room's sockets and switch the breaker back on. Plug items in one at a time, and the one that trips it again is the faulty item.

## When should I book an electrician?

Book when the simple checks do not bring the room back. Calls to MCI Electrical are answered at any time.
- **The switch trips again:** Book when the breaker drops out after one reset, or will not stay on with the room unplugged.
- **Every switch on the board is up:** Book when the board looks normal and the room is still dead. That points to a loose connection, a failed joint or a damaged cable, which only testing can locate.
- **There are signs of heat:** Book when a socket, switch or fitting smells of burning, feels warm or shows brown marks, and keep that outlet switched off until it has been tested.

## What happens on the visit?

The visit follows the circuit from the board to the dead outlet, one test at a time.
- **The failed circuit is isolated and tested:** We switch the failed circuit off at the board and test it there. Where the board layout allows, other circuits stay live so the rest of the premises keeps working.
- **The fault is traced:** Insulation resistance readings show whether current is leaking from the cable, and continuity readings show whether the cable is whole. Together they narrow the break to one outlet, joint or length of cable.
- **The part is repaired and the circuit retested:** The failed part is repaired or replaced once the rate and any parts are confirmed. The circuit is retested before it goes back on.
- **A written record is left:** Where the repair is notifiable we issue NICEIC paperwork. For smaller repairs you get a written note of the cause, the parts used and the test result.

## What does fault finding cost, and what changes it?

Fault finding is charged by the hour, and the first hour covers attendance, testing and the start of the repair. The total moves with how long the fault takes to trace and what has to be replaced.
- Commercial fault finding and repair: from £75 an hour
- The rate is put in writing before any board is opened or circuit isolated.
- Breakers, sockets and junction boxes are added to the labour, and further hours are billed after the first.
- Emergency callout has its own hourly rate, and other times of day carry a different rate that you hear from us before we set off.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Questions about a room with no power

### Should I replace the breaker myself?

No. Work on the board belongs to an electrician. A breaker that keeps tripping points to a fault, and a new one would only hide it while the fault stays in the circuit.

### Will the rest of the building stay on while you work?

Only the dead circuit is switched off, where the board layout allows it. Lights, sockets and plant on other circuits keep running unless the fault is on the incoming supply that feeds them all.

### How soon can the fault be looked at?

Calls are answered at any time, and the date is set when you book. Booked work sits in opening hours unless you ask for an emergency callout, which has a separate hourly rate.

### Do I get any paperwork after the repair?

Yes. A notifiable repair comes with NICEIC paperwork, and a smaller one with a written note of the cause, the parts used and the test result. Keep it with the building records.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical safety at work](https://www.hse.gov.uk/electricity/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)