MCI Electrical finds why power keeps cutting out by testing each circuit from the distribution board outwards, then repairs the loose joint, failing device or overloaded circuit behind it.

## Why does power keep cutting out?

Power that drops and returns usually means a protective device is reacting to a fault that only shows under certain conditions, such as heavy load, damp or heat.
- **A loose connection:** A terminal that has worked slack at a socket, switch or the board makes and breaks contact. It heats under load, so the supply fails at busy moments, and a hot joint can arc.
- **An overloaded circuit:** Heaters, machines and chargers sharing one circuit trip its breaker when they run together. The breaker is doing its job, and the answer is to split the load, not to fit a bigger breaker.
- **Equipment leaking current:** A failing appliance leaks a small current to earth and trips the RCD, the residual current device that cuts power within milliseconds. Unplugging items one at a time shows whether the kit or the wiring is to blame.
- **Damaged cable insulation:** Insulation that has aged, been nipped by a fixing or soaked by damp lets current leak to earth now and then, often after rain or once the cable warms up.
- **A tired breaker or RCD:** A protective device that has worn can trip below its rating. Testing shows whether it is the cause before anyone pays to replace it.

## What can I check safely before booking?

Looking, noting and unplugging are safe. Never open a socket, a fitting, the board or an appliance, and treat a warm outlet or a burning smell as urgent.
- **Keep a log of the cuts:** Write down the time of each cut and what was running. A pattern, such as every morning when the heating starts, tells us which circuit to test first.
- **Note which switch dropped:** Open the board door and look. Does the same breaker or the RCD drop each time? Take no covers off, and write down which switch it was.
- **Reset one time only:** Switch it back on once. If it drops again, leave it off, because every further reset puts power onto a fault that may be heating a joint.
- **Ask the neighbouring units:** If other units lose power at the same moment, the fault sits on the network and the distribution network operator for the area deals with it.

## When should I book an electrician?

Book once the cuts repeat, because an intermittent fault tends to worsen rather than clear up. Calls are answered at any time, so you can report it as it happens.
- **The same switch trips again:** Book when a breaker or RCD drops out after one reset. Something on that circuit is leaking or overloaded, and testing finds which.
- **The gaps are getting shorter:** Book when cuts come closer together. A loose joint or damaged cable gets worse with every cycle of heating and cooling.
- **There are signs of heat:** Switch the circuit off if you can do so safely when a socket feels warm, a fitting smells of burning or a cover has brown marks. Then press Book Now and say what you found.

## What happens on the visit?

The visit works through the installation circuit by circuit, starting with the one that cuts out.
- **We hear the pattern:** You tell us when the power drops and what was running. We use that to decide which circuit to test first.
- **We isolate and test:** We switch the circuit off at the board, then check insulation resistance for leakage, continuity for breaks and the RCD for its trip time. Other circuits stay on where the board layout allows.
- **We repair the fault:** Once the rate and any parts are confirmed, we remake the loose connection or replace the damaged part, then retest the circuit before it goes back on.
- **We leave a record:** A notifiable repair comes with NICEIC paperwork. For anything smaller we leave a short note naming the cause, the parts fitted and the readings.

## What affects the cost of finding the fault?

Finding an intermittent fault is charged by the hour, and the rate is given in writing before a board is opened. How long the tracing takes and which parts have failed decide the final total.
- Commercial fault finding and repair: from £75 an hour
- A fault that only appears under load can need extra time with the equipment running, which adds hours.
- Replacement breakers, sockets and RCDs are added to the labour, and bigger work the testing uncovers, such as a new board, gets a separate quote.
- Nothing is charged for a quote or for moving the booking, and there is no callout fee. Time beyond normal working hours carries a different rate that you hear first.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Questions about power cutting out

### Is it safe to keep resetting the trip switch?

Once is reasonable, to learn whether it was a single event. If it drops again, leave it off and book, because each reset puts power back onto a fault that may be heating a joint.

### Will you find the cause if the power stays on during the visit?

Insulation and RCD readings can show leakage while everything is live. If the readings come back clean, we tell you what to note down when the next cut happens.

### Could my electricity supplier be causing it?

If neighbouring premises lose power too, the fault lies with the network operator. If only your board trips, the fault is inside your installation and we test it.

### Are you NICEIC registered?

Yes, MCI Electrical is NICEIC registered, and a notifiable repair comes with the matching paperwork.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)