---
title: "Why has the power gone off in the kitchen? | NICEIC"
description: "Kitchen power loss in Eastleigh: MCI Electrical traces the fault, repairs the failed circuit or device and explains the safe checks before you book."
canonical: "https://mci-electrical.co.uk/problems/power-out-in-kitchen"
---

# Why has the power gone off in the kitchen?

> Kitchen power loss in Eastleigh: MCI Electrical traces the fault, repairs the failed circuit or device and explains the safe checks before you book.

MCI Electrical tests a workplace kitchen that has lost power, finds the failed circuit or device and repairs it where the parts allow, for businesses in Eastleigh.

## Why has only the kitchen lost power?

A kitchen usually sits on its own circuits, so one tripped device can switch off the sockets or the cooker while lights in other rooms keep working.
- **A breaker tripped on overload:** A breaker is the switch in the board that cuts a circuit when too much current flows. A kettle, urn, microwave and toaster running together on one socket circuit can trip it.
- **The earth leakage switch cut in:** An RCD is a switch that cuts power when current leaks to earth. A failing dishwasher, fridge freezer or a wet socket can trip it, and it often covers several kitchen circuits at once.
- **An appliance has a fault:** Insulation can break down inside an appliance or its lead, and the fault only shows when that plug is in use. The circuit then trips each time the item is switched on.
- **A connection has loosened or burnt:** A worn socket, a spur or the connection at a cooker switch can work loose and overheat until the circuit drops out. Heat marks or a burning smell point to this cause.
- **Water has reached the wiring:** A leaking sink, a dishwasher hose or steam and condensation near a connection can let current escape and trip the protection, often only when the kitchen is busy.

## What can I check myself when the kitchen has no power?

You can look at the board, unplug appliances and reset a switch once, all with dry hands. None of it needs a cover removed or a wire touched.
- **Find out how much is off:** Note whether only the kitchen has lost power or other rooms too. If neighbouring units are dark as well, the fault is likely in the incoming supply and not in your kitchen.
- **Look at the board:** Look for a switch sitting down or in the middle position, ideally one labelled kitchen, sockets or cooker. Do not open the board cover or touch anything behind it.
- **Unplug and reset once:** Unplug every appliance on the dead circuit, switch the tripped device back on once, then plug items in one at a time. If it trips with one appliance, leave that one unplugged.
- **Stop when it trips again:** If the switch trips at once with everything unplugged, leave it off. Never tape it on, and leave the cooker connection, gas appliances and fridge pipework alone.

## When should I book an electrician for a kitchen with no power?

Book as soon as one careful reset has not brought the power back, or at once if anything suggests heat or water at the wiring.
- **The switch will not stay on:** If the breaker or RCD trips again after one reset, something on the circuit is faulty. Resetting it repeatedly only pushes current through that fault.
- **You smell burning or see marks:** Scorch marks at a socket, or a warm or buzzing board, need attention straight away. Switch off what you can safely reach and call us, or call 999 if there is smoke or flame.
- **Food or trade is at risk:** A dead fridge freezer, or a kitchen that cannot serve, costs money by the hour. Say so when you book, so the visit can be planned around it.

## What happens when an electrician comes to a kitchen with no power?

The visit follows the fault from the board to the kitchen, one part at a time.
- **We ask what stopped and isolate the circuit:** We ask what was running when the power went and what you have already tried. Then we isolate the circuit at the board before any cover comes off.
- **We test the circuit:** We test the sockets, the cooker supply and any shared protective device, separating a faulty appliance from a fault in the fixed wiring.
- **We repair the failed part:** We replace the damaged socket, connection or device where the parts allow, and tell you what is still needed if they do not.
- **We retest and leave a note:** We test the circuit again before switching it back on, show you the working kitchen and leave a written note of the cause and the work done.

## How is a kitchen power fault priced?

Fault finding is priced by the hour, so the cost follows how long the fault takes to trace and mend, not the size of the kitchen. The hourly rate covers attending, testing the circuit and the repair itself, with parts added.
- Commercial fault finding and repair: from £75 an hour
- Nothing is charged for attending to give a quote, and rescheduling a visit costs nothing either.
- Parts and any extra time are shown to you before they are fitted or worked.
- A visit after normal working hours is charged at another rate, which you are told first.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Questions about a kitchen with no power

### Why are my kitchen sockets dead when the lights still work?

Lighting and sockets sit on separate circuits, each with its own breaker. A trip on the socket circuit leaves the lights running, and testing shows where the socket supply has stopped.

### Can one appliance cut the power to the whole kitchen?

Yes. A dishwasher, fridge freezer or urn with a fault can trip the shared protective switch and take every socket on it too. Unplugging items before one reset helps show which.

### Is it safe to keep resetting the switch?

No. One careful reset after unplugging is reasonable. If it trips again, leave it off, because each reset sends current through the fault and can heat the connection.

### Can the fault be repaired on the same visit?

Where the failed part is small, such as a socket or a connection, we can change it during the visit when the part is to hand. A larger fault, such as damaged cable, is explained and priced before any further work.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)
