# Why an RCD trips at night

> RCD trips at night: the usual causes, checks you can make safely and how MCI Electrical, NICEIC registered, tests for the fault around Eastleigh.

An RCD that trips at night is usually reacting to something that switches on after closing, such as a timed heater or a freezer, and MCI Electrical tests the circuits to find which one carries the fault.

## Why does an RCD trip only at night?

Few loads run overnight and most of them sit on timers, so the clock time of the trip is the first clue to the cause.
- **An immersion heater on a timer or Economy 7:** Economy 7 is a cheap overnight electricity tariff, and water heaters on it come on at the changeover. An element with worn insulation leaks current to earth as soon as it heats.
- **A fridge or freezer compressor starting:** A compressor cycles on and off through the night. A motor with a developing earth fault trips the RCD when it starts, and nobody is awake to see which unit did it.
- **Heating or a dehumidifier on a timer:** Boilers, electric heaters and dehumidifiers on a timer start together at set times. Any one that leaks to earth takes the circuit down the moment it switches on.
- **Damp in outdoor fittings and sockets:** As the air cools, condensation settles in external lights, sockets and junction boxes. Moisture gives current a path to earth, which is why these trips land in the small hours.

## What can I check safely when it trips at night?

These checks involve only a clock, a plug and the timer settings, so nothing is opened and no wiring is touched.
- **Note the time of each trip:** Write down when the RCD trips, reading it from a clock that has stopped or reset. A trip at the same minute every night points to a timer.
- **Compare it with timers and the tariff:** Look at the time settings on heating, water heaters and the Economy 7 changeover, and see whether any of them match the time you noted.
- **Unplug one timed item each night:** Unplug a portable timed item such as a dehumidifier or heater, one per night, and reset the RCD once. If the trips stop, leave that item unplugged and tell us which one it was.

## When should I book an electrician for night trips?

Book as soon as a pattern shows. Book Now takes the details at any hour, because our assistant answers calls day and night.
- **The trips repeat every night:** A trip every night means a fault shows itself each time something switches on, and unplugging timed items has not removed it.
- **Overnight equipment depends on that circuit:** Freezers, alarms, security systems and monitoring equipment lose power when the RCD drops, so book rather than wait for the next trip.
- **There is heat, damage or a burning smell:** Leave the RCD off, do not reset it again and call straight away.

## What happens when you attend an RCD that trips at night?

We start from the trip times you noted, because they decide which circuits and loads are tested first.
- **Going through the trip pattern:** We ask when it trips, what runs at that time and what you have already unplugged. That narrows the list of circuits before any testing starts.
- **Isolating and testing circuits:** We switch off one circuit at a time and test each with insulation resistance readings, which show where current is leaking to earth. Circuits on other ways stay live where the board layout allows.
- **Testing the suspect load:** Immersion elements, compressors and timed heaters are tested on their own until the leaking one shows up. A fault that comes and goes can have a data logger fitted to record exactly when it trips.
- **Repairing and leaving a note:** Once the cause is found we repair it and test the circuit again. You keep a short written note of the cause, the parts used and the test readings.

## How is RCD fault finding priced?

Fault finding is charged by the hour, and the hours cover attending, testing the circuits and doing the repair. Trips that are hard to catch can take longer, which adds hours.
- Commercial fault finding and repair: from £75 an hour
- There is no callout fee, and quotes and rescheduling cost nothing.
- Emergency callouts carry their own hourly rate, and we tell you what it is before we set off.
- A part found faulty, such as an element or a protective device, is added to the bill after the testing.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Questions about an RCD tripping at night

### Why does my RCD only trip at night?

Something is switching on overnight. Timed heaters, immersion elements, compressors and damp outdoor fittings are the usual suspects, and the time of the trip tells us which to test first.

### Can an outdoor light or socket trip the RCD at night?

Yes. Condensation settles in outdoor fittings as the air cools and lets current leak to earth. Testing the circuit shows whether a fitting is wet or failing.

### Could the Economy 7 changeover cause it?

Yes, when a water heater or storage heater switches on at the changeover with a leak to earth. We test the heater and its circuit, and your energy supplier deals with the meter itself.

### Will my freezer lose power when the RCD trips?

Yes, if it shares the circuit that trips. Everything on that circuit stays off until the RCD is reset, so book soon if the freezer matters to you.

### How do you catch a trip that comes and goes?

We fit a data logger to the circuit. It records when the trip happens, so a fault that only appears while nobody is watching still gets caught and tested.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.

## Sources
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)
- [NICEIC: Householder Guidance](https://niceic.com/householders/)
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)