# RCD tripping when it rains

> RCD tripping when it rains at an Eastleigh business: why water trips it, what to check safely and how MCI Electrical finds the fault. · Call 07366 896562

An RCD trips in the rain when water gives current a path to earth at an outside socket, light, joint or cable. MCI Electrical tests the circuit to find that fault at commercial premises in Eastleigh.

## Why does my RCD trip when it rains?

An RCD is the safety switch that cuts the supply when current escapes from where it should run. Rain finds the weak point in an outdoor circuit.
- **Car park and building lights:** Wall lights, bollards and flood lights let rain past a split gasket or a loose cable entry. The wet fitting leaks to earth and the RCD switches the whole lighting circuit off.
- **Yard and loading bay sockets:** Sockets used for tools, pressure washers and vehicle chargers collect water behind lids that no longer close. Wet pins and terminals trip the RCD, often with a plug in item connected.
- **Cable joints and glands:** A cable gland is the seal where a cable enters a box or machine. Where one has perished, or a joint was never made watertight, rain creeps along the cable to the live conductors.
- **Roof and external plant:** Extractor fans, air conditioning units, signs and shutter motors sit in the weather. Rain reaching their terminals or motor windings trips the RCD that protects their supply.
- **A worn RCD:** An ageing RCD can trip in damp air while the circuit behind it tests clear. Checking the device and the cables separately shows which of the two has failed.

## What can I safely check when my RCD trips in the rain?

Look and make notes only. Leave covers on, leave wet fittings alone and never touch wiring or the inside of the board.
- **Note when it trips:** Write down whether it trips during the rain, after it, or only when one outside light or machine is switched on. That pattern points towards the faulty circuit.
- **Unplug outside items:** Pull plugs from yard sockets, including tools, chargers and extension leads, if you can reach them dry. Then reset the RCD once. If it trips again, leave it off.
- **Look from a distance:** Look at outside lights, sockets and plant for cracked covers, open lids, dripping water or scorch marks. Keep your hands off anything wet.
- **Note what lost power:** List the rooms, tills, lights and machines that went dead. That shows which circuits sit behind the RCD that tripped.

## When should I book an electrician for an RCD that trips in the rain?

Book Now if the RCD trips a second time, or if anything outside is wet, damaged or warm to the touch.
- **It trips again after one reset:** A second trip means the leak is still there. Leave the RCD off and the affected circuit unused until it has been tested.
- **Water or damage at a fitting:** Water inside a light, socket or enclosure, a cracked cover or a pulled cable needs testing before anyone uses that circuit again.
- **Heat, a buzz or a burning smell:** A warm board, humming or a burnt smell can mean a loose connection that is arcing. Stop resetting, leave it off and book.
- **Trading depends on that circuit:** Tills, chillers, alarms and machines stop when their circuit goes off. A visit traces the leak so the circuit is not reset day after day.

## What happens on a visit for an RCD that trips in the rain?

We start at the board with whoever knows the premises, then follow the tripped circuit outwards until the leak has a named cause.
- **Find the tripped circuit:** We note which RCD or breaker has operated and what lost power, then switch that circuit off and prove it dead before any cover comes off.
- **Test the cable and fittings:** An insulation resistance test measures leakage between the conductors and earth with the supply off. We repeat it along the circuit to narrow down the light, socket, joint or plant at fault.
- **Repair the failed part:** We replace or reseal the part that failed, such as a gasket, gland, socket or joint, once you say go ahead. Other circuits stay live where the board layout allows.
- **Test again and record it:** We test the circuit once more and leave a written note of the cause, the parts used and the readings. NICEIC paperwork follows where the repair is notifiable.

## What does tracing an RCD trip cost and what changes it?

The hourly rate for commercial fault finding covers attendance, testing and the repair time needed to trace why the RCD trips. The total moves with how long the leak takes to find, the parts it needs and the hours the work is done in.
- Commercial fault finding and repair: from £75 an hour
- A single wet light takes less time than a leak somewhere along a long outdoor cable.
- Replacing a failed RCD or distribution board is priced as separate work, apart from the hours spent finding the fault.
- An emergency callout carries its own hourly rate, which we tell you before we set off.

## Electrical fault finding near you
- [Electrical fault finding in Chandler's Ford](https://mci-electrical.co.uk/commercial-electrician-chandlers-ford/commercial-fault-finding)
- [Electrical fault finding in Hedge End](https://mci-electrical.co.uk/commercial-electrician-hedge-end/commercial-fault-finding)
- [Electrical fault finding in Southampton](https://mci-electrical.co.uk/commercial-electrician-southampton/commercial-fault-finding)

## Your questions about RCDs tripping in wet weather

### Why does my RCD only trip when it is raining?

Water finds a weak seal, a cracked cover or damaged cable and lets a small current escape to earth. The RCD senses the escape and cuts the supply. When the weather dries the leak stops, which is why the fault seems to come and go.

### Is it safe to keep resetting the RCD?

No. Reset it once at most, with outside plugs removed. If it trips again the leak is still there, so leave it off and have the circuit tested.

### Will the rest of the building lose power while you work?

That depends on how the board is split. Where the affected circuit has its own way we switch off only that one, and the rest of the building carries on.

### Can you repair the fault on the same visit?

Where the failed part is a seal, socket, joint or fitting, we can repair it once you say go ahead. A new cable or a new board is a larger job, so it is quoted separately first.

## Related problems
- [Circuit breaker keeps tripping](https://mci-electrical.co.uk/problems/circuit-breaker-keeps-tripping): A breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- [Consumer unit tripping with nothing plugged in](https://mci-electrical.co.uk/problems/consumer-unit-tripping-nothing-plugged-in): A trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- [Cooker switch not working](https://mci-electrical.co.uk/problems/cooker-switch-not-working): Power to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- [Fuse keeps blowing](https://mci-electrical.co.uk/problems/fuse-keeps-blowing): Repeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- [Lights not working but sockets are fine](https://mci-electrical.co.uk/problems/lights-not-working-but-sockets-are): Sockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- [MCB keeps tripping in a commercial building](https://mci-electrical.co.uk/problems/mcb-keeps-tripping): A tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.

## Sources
- [BS 7671: IET Wiring Regulations (18th Edition)](https://electrical.theiet.org/bs-7671/)
- [HSE: Electrical Safety at Work](https://www.hse.gov.uk/electricity/)
- [Electrical Safety First: Safety Guidance](https://www.electricalsafetyfirst.org.uk/guidance/)

Updated 2026-11-20.

[Electrical fault finding](https://mci-electrical.co.uk/services/commercial-fault-finding)

## Book or ask a question
- [Book Now](https://mci-electrical.co.uk/#chat)