CCTV no picture or image
A CCTV camera shows no picture when it loses power, its cable fails or the recorder stops showing it. MCI Electrical tests each in turn and tells you which part has failed.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why does my CCTV camera show no picture?
A blank view means the picture is stopping somewhere between the camera lens and the screen you watch. Five faults account for most black screens.
- The camera has lost powerA failed power adaptor, a loose low voltage connector or a tripped supply leaves the camera dead. Look for the small status light, or the red glow of the infrared lamps at night.
- The video cable is damagedCoax or network cable can be crushed, cut by a drill, chewed or corroded at a joint. The camera stays powered but the recorder receives nothing from it.
- Water has got into the cameraA perished seal or an open cable entry lets moisture into the housing. The picture goes foggy first, then fades to black, and a wet camera that is still powered can short out.
- The lens, sensor or night lamps have failedA camera can power up and send a dark or smeared image when its sensor is worn out. Failed infrared lamps leave the night view black while the day view looks normal.
- The recorder or monitor is set wrongA monitor on the wrong input shows black although every camera is working. A recorder that has reset after a power cut can also lose its camera channels.
What can I check safely when CCTV has no picture?
Stay with what you can see and reach without opening any equipment or touching mains wiring. These checks sort a screen setting from a real fault.
- Count the blank camerasFlick through every view on the recorder. One blank view points to that camera or its cable, while every view blank points to the recorder, the monitor or a shared power supply.
- Choose the right monitor inputUse the monitor's own remote or buttons to select the input the recorder is plugged into. Do not take the cover off the monitor or pull its power lead.
- Look at the plugs you can reachCheck that the video lead and the power lead sit fully home at the recorder and monitor. Leave any cable with cracked insulation, bare metal, scorch marks or damp alone.
- Watch the camera at duskA camera with no status light and no infrared glow after dark has no power. If you can see water inside the housing, do not touch it and keep clear until it is tested.
When should I book an electrician for a CCTV black screen?
Book when the safe checks have not brought the picture back, or when the fault sits in fixed wiring, at height or in a wall.
- Every camera is blankSeveral cameras failing together points to the recorder, a shared power supply or a main cable run, and each of those needs testing with meters rather than guessing.
- One camera stays blankA single dead view with the cables seated needs the power at that camera and the cable back to the recorder tested, so the camera is not replaced when the cable is the fault.
- The fault is out of reachA hardwired supply, cable running inside walls or underground, or a camera mounted high on a gable or gantry needs an electrician with the right access equipment.
- There is damage or waterA hanging camera, split cable, loose outdoor fitting or any water around live equipment needs to be made safe before the system is switched back on.
What happens when MCI Electrical visits a CCTV fault?
The visit follows the picture backwards from the screen to the camera, so the fault is pinned to one part before anything is replaced.
- Screen and recorder firstWe check the monitor input, the recorder display and each camera channel to see whether the system is receiving any picture at all.
- Power tested at the cameraWe measure the supply reaching the affected camera and its power unit, which tells us at once whether the camera has power or the feed has failed.
- Cable and picture signal checkedWe test the video cable between the camera and recorder for breaks and poor joints, and inspect the camera for water, a damaged lens or failed infrared lamps.
- The fault explained before workWe tell you which part has failed and what putting it right involves, whether that is a connection, a power unit, a cable or a replacement camera, before any further work starts.
What does the price for a CCTV fault visit cover?
The price shown covers coming out, testing the power, cable, camera and recorder linked to the missing picture, and finding which part has failed. It changes when the fault needs a replacement camera, power unit, cable repair or recorder, because those depend on what the tests show.
From £1,450
£1,450: 4 included (camera); £325 for each additional one.
Included
- Walk round to mark camera positions and cable routes on the building
- Cameras, brackets and weatherproof fittings for the quoted number of views
- Cabling from each camera back to the recorder
- Recorder setup, date and time, and a working live view on site
- A walk through so you can pull up each camera yourself
Not included
- A staffed monitoring station or someone watching the screens for you
- Digging through tarmac, new poles or a separate data contract for remote viewing
- A maintenance plan. We do not sell one.
- Quotes are free, rescheduling is free and there is no callout fee.
- Work outside your trading hours is charged at a different rate, and we tell you what it is before we set off.
- Replacement cameras, power units, cables and recorders are priced once testing shows which part failed.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
CCTV installation near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowWhy has only one of my CCTV cameras gone black?
One blank camera points to that camera, its power supply or the cable back to the recorder, because the recorder and the other views are working. Testing the power and the cable separates a dead camera from a damaged lead.
Should I replace a camera that shows no picture?
Cameras are normally replaced rather than repaired, but a new one will not help if the cable or power unit is the fault. Testing first shows whether the camera needs replacing, and a new camera often works with the recorder you already have.
Can water damage a CCTV camera?
Yes. Even outdoor cameras let water in when a housing seal perishes or the cable entry is not sealed properly. The picture goes foggy before it fails, and the camera should be left alone until it has been tested.
Why does my phone app show nothing when the recorder screen works?
The recorder is receiving pictures, so the cameras and cables are fine. The break is in the network link that carries the picture to your phone, such as the router, the internet connection or the recorder's network settings.
Related problems
- Why is my CCTV not working?A blank camera view or missing footage traces to camera power, the cabling or the recorder, and each part is tested separately on site.
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Circuit breaker won't reset or trip switch won't go back upA breaker that springs back means a live fault or a failed device; testing separates the two before anything is repaired.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Fuse keeps blowingRepeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
Sources
- Electrical Safety First: Safety Guidance
- BS 7671: IET Wiring Regulations (18th Edition)
- HSE: Electrical safety at work
Updated 20 November 2026