Fuse keeps blowing
A fuse keeps blowing when the circuit or item behind it draws more current than the fuse allows. MCI Electrical tests the circuit at your premises to find which it is and fix it.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why does my fuse keep blowing?
A fuse is a deliberate weak point that melts when more current flows than the circuit or the appliance can safely carry.
- Too many items on one socketSeveral heaters, kettles or a dryer on one adaptor can draw more than the fuse is rated for. The fuse melts after a few minutes of use instead of straight away.
- A fault inside one applianceA failing motor, element or power supply pulls too much current or shorts inside its casing. A new fuse then blows the moment that item is switched on.
- A short circuit in a flex or cableCrushed or chafed insulation lets live and neutral touch. The fuse blows instantly, often with a bang or a scorch mark at the plug.
- The wrong fuse fittedA fuse rated too low for the appliance blows under normal use, while one rated too high stops protecting the flex. The rating on the appliance label decides which fits.
- A worn fuse boardOlder boards use rewirable fuse carriers, where a strip of fuse wire is threaded between two screws. Wire of the wrong thickness or a loose screw makes the same fuse blow again and again.
What can I check safely when a fuse keeps blowing?
You can note what was running, read the appliance label and take items out of use without opening an appliance, a plug or the fuse board.
- Note what was runningWrite down which appliance or machine was on when the fuse blew, and whether it went at once or after a while. A quick blow points to a short and a slow one to overload.
- Read the rating on the labelThe label gives the power in watts or the current in amps. A heater or kettle needs a higher rated fuse than a lamp or a charger, and the label tells you which.
- Take the item out of useUnplug any appliance whose fuse has blown more than once and leave it unplugged. Do not swap in a bigger fuse to get it running, because the flex would then be the weak point.
When should I book an electrician for a fuse that keeps blowing?
Book Now when a new fuse blows straight away, when a fuse at the board is the one going, or when anything smells of burning.
- A new fuse blows straight awayThat means a short circuit somewhere on the circuit or in the item plugged into it, and the cause needs finding before anything is switched on again.
- The fuse board keeps losing a fuseA board fuse protects a whole circuit and its cable. Repeated blowing there needs the circuit tested, not another length of fuse wire.
- There is a scorch mark or burning smellHeat at a plug, socket or fuse holder points to a loose connection or an overloaded part. Leave it off and book.
What happens on a visit for a fuse that keeps blowing?
We begin with which fuse goes, how soon after switching on, and what is connected, then test the circuit from the board out to the last socket.
- Isolate and prove the circuit deadWe switch off the supply to the circuit and confirm it is dead with a tester before touching anything. That keeps the work safe and the premises protected.
- Test for a short and measure the loadAn insulation resistance test checks the cable for a short or a leak to earth. We then add up what the circuit feeds and compare it with the fuse rating.
- Check the fuse, flex and connectionsWe confirm the fuse or fuse wire is the right rating, inspect plugs and flexes for damage, and tighten or replace any connection showing heat marks.
- Repair and leave a written noteOnce you say go ahead we make the repair, test the circuit again and leave a written note of the cause and the readings.
What affects the price of tracing a fuse that keeps blowing?
The hourly rate for commercial fault finding covers attending and testing until the cause is found. What you pay moves with how long the trace takes, which parts are needed and the hours the visit falls in.
From £75 an hour
Included
- Attendance at the workplace and a talk through the symptoms with whoever is on site
- Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
- Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
- A written note of the cause, the work done and any further parts still needed
- NICEIC documentation where the repair is notifiable
Not included
- A full fixed wire inspection of every circuit on the premises
- Rewiring a whole board or installing a new three phase supply as part of the same hour
- IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
- A visit outside normal trading hours carries a different rate, which we give you before we leave for the premises.
- Replacing a worn fuse board or fitting a modern consumer unit is quoted separately from the fault finding.
- There is no callout fee, and moving a booked visit to another day costs nothing.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowCan I fit a higher rated fuse to stop it blowing?
No. The fuse is sized to protect the flex or the cable, so a larger one lets that overheat before anything blows. We find why the current is too high and fix that.
Why does the fuse blow when two heaters run together?
Together they draw more current than the socket and fuse are rated for. Running them on separate sockets or circuits usually settles it, and we test the circuit to confirm it can carry the load.
Is a blown fuse dangerous?
The fuse has done its job by cutting the supply, so the blow itself is the safe part. Resetting or replacing it without finding the cause is what risks overheating, so keep the item off until it is tested.
Do you test fuse boards in shops and offices?
Yes, we test and repair circuits in shops, offices and other business premises. Tell us which fuse blows and what was running when you book.
Related problems
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Lights not working but sockets are fineSockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- MCB keeps tripping in a commercial buildingA tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
- No power in one room of a commercial buildingPower stops in one room when the circuit feeding it trips or fails, and testing from the board finds where.
Sources
- Electrical Safety First: Plugs and fuses (BS 1362 fuse ratings)
- Electrical Safety First: Overloading sockets
- BS 7671: IET Wiring Regulations (18th Edition)
Updated 20 November 2026