MCB keeps tripping in a commercial building
An MCB trips when its circuit is overloaded or faulty. MCI Electrical tests the tripping circuit from the board outwards for businesses in Eastleigh and tells you which it is.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why does an MCB keep tripping?
An MCB, or miniature circuit breaker, is the switch on the distribution board that cuts one circuit when the current climbs too high. Repeat trips come from a handful of causes.
- Too much equipment on one circuitHeaters, kitchen appliances, chargers and screens added over time can together draw more than the circuit's rating. The breaker then drops out after a few minutes, or when the last item is switched on.
- A motor or compressor starting upMotors, compressors and extraction fans pull several times their running current for a moment as they start. A breaker sized close to the load can drop out on that surge each time the machine starts.
- A short circuit in a cable or accessoryLive and neutral touching inside a damaged socket, a pinched cable or a wet junction box send a heavy current through the breaker at once. The MCB then trips the instant it is switched back on.
- A loose connection running hotA terminal that has worked loose heats up under load. That heat can trip the breaker and may leave marks on the terminal, the accessory or the board.
- A breaker that has worn outAn MCB that has tripped many times, or has overheated, can start dropping out below its rating. Testing shows whether the breaker or the wiring is at fault, so a sound breaker is not replaced for nothing.
What can a business check safely before calling an electrician?
Every check below happens outside the board with its cover shut. Never open a distribution board, a socket or a switch, and leave anything that smells burnt alone.
- Note what was runningWrite down which equipment was on, and whether the breaker dropped out at once or after some minutes. An instant trip points to a short circuit, and a delayed one points to overload.
- Unplug portable equipment on that circuitPull the plugs of heaters, kettles, chargers and tools served by the tripping circuit. Leave fixed machines and lights alone, because they are wired in and need an electrician.
- Reset the breaker onceSwitch the MCB fully off, then on, one time. If it drops out again, leave it off, because it is stopping a fault that a second reset will not cure.
- Look without touchingCheck the closed board and the nearby sockets for brown marks, warmth or a burnt smell. Anything that shows heat stays switched off until it has been tested.
When should you book an electrician for a tripping MCB?
Book as soon as one reset does not hold, or the breaker will not switch on at all. Our line answers calls at any time.
- It trips again after one resetA breaker that drops out a second time is reporting a fault or a steady overload. The circuit needs testing before anyone relies on it.
- It trips the moment you switch onAn instant trip points to a short circuit in the wiring or an accessory, and an electrician has to trace it with test instruments.
- Lights, sockets or a machine stay deadWhen part of the premises has no power and a reset changes nothing, the cause sits further along that circuit.
- There is heat, marks or a burnt smellSwitch that circuit off and keep it off. Those signs mean a connection or cable is overheating.
What happens when an electrician finds why the MCB trips?
We begin at the breaker and work outwards along the circuit it protects.
- We ask what was running and isolate the circuitWe ask what was on when it tripped, then switch the circuit off at the board so testing is safe. Neighbouring circuits stay on where the board is laid out to allow it.
- We test the wiring and the loadInsulation resistance and continuity readings show whether current leaks or shorts along the cable. We also check the breaker, the accessories and the equipment on the circuit against its rating.
- We repair once the hourly rate is statedThe faulty part is repaired or replaced after you have the rate in writing, then the circuit is tested again before it goes back on.
- We leave a written noteYou receive a note naming the cause, the parts fitted and the readings, plus NICEIC paperwork when the repair is notifiable.
What does MCB fault finding cost and what changes the price?
Fault finding is charged by the hour, and the live price shows the starting rate. That rate covers attendance, testing and the opening stretch of repair, and the final total follows how long the fault takes to trace.
From £75 an hour
Included
- Attendance at the workplace and a talk through the symptoms with whoever is on site
- Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
- Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
- A written note of the cause, the work done and any further parts still needed
- NICEIC documentation where the repair is notifiable
Not included
- A full fixed wire inspection of every circuit on the premises
- Rewiring a whole board or installing a new three phase supply as part of the same hour
- IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
- A short circuit at an accessory within easy reach takes less time than a fault buried along a long cable run.
- Replacement breakers, sockets and cable are added to the labour once testing shows what has failed.
- An emergency callout has its own hourly rate, there is no callout fee, and you hear the rate before we set off.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowCan I fit a bigger MCB to stop it tripping?
No. A breaker's rating is matched to the cable it protects, and a larger one lets an overloaded cable overheat instead of tripping. We find the cause and, if the load is too big, price a new circuit.
Do I have to shut the business while the circuit is tested?
Only the tripping circuit goes off while we test it, provided the board is wired so each way stands alone. Everything on the other ways keeps working.
Is there a charge for a quote or a callout?
Quotes are free, rescheduling is free and there is no callout fee. Fault finding is then charged by the hour.
Can the fault be fixed in one visit?
Yes, when the part is on the van or at a local merchant. A new circuit or a long cable run gets its own written price first.
Related problems
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Fuse keeps blowingRepeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- Lights not working but sockets are fineSockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- No power in one room of a commercial buildingPower stops in one room when the circuit feeding it trips or fails, and testing from the board finds where.