No power in one room of a commercial building

When one room loses power while the rest of the building works, the fault sits on that room's circuit. MCI Electrical tests the circuit from the board outwards to find the failed part.

Calls answered 24/7

  • 17 years trading
  • Local to Eastleigh

What makes a single room go dead at work?

Each room hangs off its own circuit, so a fault on that circuit darkens that room alone. The cause is one of a handful of failures, and testing tells them apart.

  • A breaker has trippedThe switch for the circuit sits on the distribution board, the cabinet that splits the supply into separate circuits. It drops out when the circuit overloads or leaks current to earth, and everything on that circuit goes off together.
  • A loose connection at a socket or switchA terminal that has worked loose or scorched at one outlet can cut the supply to every outlet beyond it on the same cable. The board shows nothing wrong while the room stays dead.
  • A joint has failed in a junction boxCables meet in junction boxes above ceilings or behind panels. A joint that fails there stops the lights or sockets it feeds, even though every switch on the board looks normal.
  • A cable has been damagedA fixing driven through a cable, or a run pinched during building work, can break the circuit or let current leak. The room goes dead from the day the damage happens.
  • Something plugged in has failedA faulty heater, kettle or charger can trip the circuit it is plugged into. Unplugging the equipment shows whether the item or the wiring is to blame.

What can I safely check before booking?

Looking and switching are the only safe checks. Never open a socket, a switch, a light fitting or the board itself, and leave anything that smells of burning alone.

  • Look at the boardOpen the door of the distribution board and look for a switch sitting in the off or middle position. Take no covers off.
  • Reset it oncePush that switch fully off, then on, one time only. If it drops out again, leave it off, because a breaker that keeps tripping is shutting the circuit down to stop a fault.
  • Unplug the roomUnplug everything from that room's sockets and switch the breaker back on. Plug items in one at a time, and the one that trips it again is the faulty item.

When should I book an electrician?

Book when the simple checks do not bring the room back. Calls to MCI Electrical are answered at any time.

  • The switch trips againBook when the breaker drops out after one reset, or will not stay on with the room unplugged.
  • Every switch on the board is upBook when the board looks normal and the room is still dead. That points to a loose connection, a failed joint or a damaged cable, which only testing can locate.
  • There are signs of heatBook when a socket, switch or fitting smells of burning, feels warm or shows brown marks, and keep that outlet switched off until it has been tested.

What happens on the visit?

The visit follows the circuit from the board to the dead outlet, one test at a time.

  • The failed circuit is isolated and testedWe switch the failed circuit off at the board and test it there. Where the board layout allows, other circuits stay live so the rest of the premises keeps working.
  • The fault is tracedInsulation resistance readings show whether current is leaking from the cable, and continuity readings show whether the cable is whole. Together they narrow the break to one outlet, joint or length of cable.
  • The part is repaired and the circuit retestedThe failed part is repaired or replaced once the rate and any parts are confirmed. The circuit is retested before it goes back on.
  • A written record is leftWhere the repair is notifiable we issue NICEIC paperwork. For smaller repairs you get a written note of the cause, the parts used and the test result.

What does fault finding cost, and what changes it?

Fault finding is charged by the hour, and the first hour covers attendance, testing and the start of the repair. The total moves with how long the fault takes to trace and what has to be replaced.

From £75 an hour

Included

  • Attendance at the workplace and a talk through the symptoms with whoever is on site
  • Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
  • Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
  • A written note of the cause, the work done and any further parts still needed
  • NICEIC documentation where the repair is notifiable

Not included

  • A full fixed wire inspection of every circuit on the premises
  • Rewiring a whole board or installing a new three phase supply as part of the same hour
  • IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
  • The rate is put in writing before any board is opened or circuit isolated.
  • Breakers, sockets and junction boxes are added to the labour, and further hours are billed after the first.
  • Emergency callout has its own hourly rate, and other times of day carry a different rate that you hear from us before we set off.
  • Fixed wire testing is priced on the number of boards and circuits, not by the hour.
  • Emergency lighting is priced per light, and the three hour test is priced separately.
  • Repairs are priced item by item off the report, so you choose what to do and when.
  • Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
  • Quotes are free, rescheduling is free, and there is no callout fee.

Electrical fault finding near you

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose MCI Electrical

Photo of David McInnesDavid McInnesElectrician
Trading since
2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”

David McInnes, MCI Electrical

Book Now

Questions about a room with no power

Still have a question?

Should I replace the breaker myself?

No. Work on the board belongs to an electrician. A breaker that keeps tripping points to a fault, and a new one would only hide it while the fault stays in the circuit.

Will the rest of the building stay on while you work?

Only the dead circuit is switched off, where the board layout allows it. Lights, sockets and plant on other circuits keep running unless the fault is on the incoming supply that feeds them all.

How soon can the fault be looked at?

Calls are answered at any time, and the date is set when you book. Booked work sits in opening hours unless you ask for an emergency callout, which has a separate hourly rate.

Do I get any paperwork after the repair?

Yes. A notifiable repair comes with NICEIC paperwork, and a smaller one with a written note of the cause, the parts used and the test result. Keep it with the building records.