Lights not working but sockets are fine
When the lights are out and the sockets still work, the fault sits on the lighting circuit alone. MCI Electrical traces it from the board outwards and puts the lights back on.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why do my lights fail when the sockets still work?
Lights and sockets run on separate circuits from the board, so one can fail while the other carries on. These are the usual reasons the lighting side stops.
- The lighting breaker has switched offA breaker is the switch in the board that cuts a circuit when something is wrong. If the lighting one has dropped, every light on it goes dark while the sockets stay live.
- A fitting has failedA burnt lamp holder or a dead driver, the small box that powers an LED, can trip the circuit as it fails. One bad fitting can take the whole run with it.
- A connection has worked looseLights are joined at ceiling roses, switches and junction boxes. When one connection loosens or overheats, everything beyond it goes out and the rest of the circuit may still work.
- A cable above the ceiling is damagedCable in a ceiling void or loft can be nicked by other trades, crushed or chewed. A break there cuts off every light downstream while nothing shows in the room.
What can I safely check when the lights are out?
Safe checks need no tools and no covers off. Stop at the first sign of heat, a burning smell or a buzzing board.
- Look at the lighting breakerOpen the board door only if it opens without a tool. If one breaker sits down, push it up once. If it drops again straight away, leave it off.
- Try the lights one at a timeSwitch every light off, reset the breaker, then switch them on one by one. The light that makes the breaker drop is the one to leave off and tell us about.
- Swap a lamp in a cool fittingWith the switch off and the fitting cool, fit a new lamp of the same type. Do not open the fitting itself or touch any wiring behind it.
When should I book an electrician for dead lights?
Book Now when a reset does not hold, or when a whole room or floor stays dark after a new lamp.
- The breaker drops again after a resetA breaker that keeps dropping is reacting to a real fault on the lighting cable or a fitting. Leave it off and let it be tested.
- Heat, a buzz or a burning smellA warm switch, a hum from the board or a scorched smell points to a failing connection. Switch the lighting breaker off and keep clear until it is checked.
- The problem began after other workIf the lights failed soon after building work, a new fitting or a DIY change, the cause is probably in that work. Tell us what was done.
What happens when MCI Electrical attends dead lights?
We start at the board and follow the lighting circuit out to the dark rooms, then repair the part the tests name.
- We read the board and the symptomsWe ask which rooms are dark and what was tried, then read the breakers. Live sockets show the supply into the board is fine.
- We isolate and test the lighting circuitWe switch the lighting way off and test the cable with instruments. The readings show a break, a short or a leak to earth.
- We check each connection along the runSwitches, roses and junction boxes on the failed run are opened and tested in turn. That shows which fitting or joint has failed.
- We repair and leave a written noteWe replace the failed part, retest the circuit and leave a note of the cause, the parts used and the test result. NICEIC paperwork follows where the repair needs it.
How is finding a lighting fault priced?
Fault finding is charged by the hour, because nobody can say in advance how long a break takes to trace. The first hour pays for attending, testing and the first repair we can finish.
From £75 an hour
Included
- Attendance at the workplace and a talk through the symptoms with whoever is on site
- Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
- Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
- A written note of the cause, the work done and any further parts still needed
- NICEIC documentation where the repair is notifiable
Not included
- A full fixed wire inspection of every circuit on the premises
- Rewiring a whole board or installing a new three phase supply as part of the same hour
- IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
- We state the hourly rate before we set off, and there is no callout fee.
- Replacement parts and any later hours are charged on top, and we explain each before it starts.
- Work done out of hours has its own rate, which we tell you beforehand.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowIs it dangerous if my lights are off but the sockets work?
It is not an emergency, but a lighting circuit that has failed has a fault that needs finding. Use a torch and take care on stairs. Do not keep resetting a breaker that drops.
Could it just be the lamps?
If one light is out, yes. If a whole room or floor is dark together, the cause is the circuit, and new lamps will not fix it.
Can you fix lighting faults in offices and shops?
Yes. Tracing faults on commercial installations is what MCI Electrical does, and the company is NICEIC registered. You deal with us from the first call to the repair.
Do you charge a callout fee?
No. Fault finding is priced by the hour, and the rate is stated before we set off. Rescheduling a visit is free.
Related problems
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Fuse keeps blowingRepeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- MCB keeps tripping in a commercial buildingA tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
- No power in one room of a commercial buildingPower stops in one room when the circuit feeding it trips or fails, and testing from the board finds where.
Sources
- BS 7671: IET Wiring Regulations (18th Edition)
- Electrical Safety First: Safety Guidance
- NICEIC: Householder Guidance
Updated 20 November 2026