Why has half the house lost its electricity?

Electricity reaches a building through several circuits, each guarded by a switch on the board. When one group fails, the part it feeds goes dark and the rest carries on.

  • A residual current device has trippedA residual current device, or RCD, is a switch that cuts power when current leaks to earth. Boards often have two, each guarding a different group of circuits, so one tripping darkens its group.
  • Several circuit breakers have dropped outA circuit breaker drops out when its circuit is overloaded. Two or three going together on one side of the board can take that whole side down.
  • An appliance is the real faultA failing heater, kettle or charger can trip the switch that guards every circuit sharing its protection, so the dead half is the result and the appliance is the cause.
  • A connection in the board has worked looseA terminal that has loosened or scorched can drop a group of circuits, and the supply may come back after a reset and fail again. Only testing finds it.
  • A second board has lost its feedSome buildings have a sub board, a smaller board fed from the main one. If that feed fails, everything on the sub board goes dead together.

What can I safely check when half the house has no power?

Looking and switching are safe. Opening anything is not, so leave every cover, socket and fitting closed.

  • Look for a switch that has movedOpen the door of the board, where it has one, and look for a switch sitting down or halfway. Take no cover off and touch nothing else.
  • Unplug the dead sidePull the plugs of heaters, kettles, chargers and other portable items on the dead side before any reset, because one of them is often what tripped the switch.
  • Reset once and stopPush a tripped switch fully down, then up, one time. If it drops again, leave it down, because it is stopping a fault from carrying on.
  • Watch for heat or a burning smellWarm sockets, brown marks or a scorched smell mean that outlet stays switched off until it has been tested.

When should I book an electrician?

Book when one reset does not bring the power back. Calls are answered at any time.

  • The switch will not stay onBook when it drops again straight after a reset, or when it will not stay up even with the dead side unplugged.
  • The board looks normalBook when every switch is up and half the house is still dead. A loose connection or a lost feed is the likely cause, and only testing locates it.
  • Heat, damp or burningBook at once when a smell of burning, a warm board or water near a socket goes with the power loss, and leave that circuit off.

What happens when we visit?

We start at the board and follow the dead circuits outwards, one test at a time.

  • The dead circuits are switched off and testedWe switch the affected circuits off at the board and test them there. Where the board allows, the circuits that still work stay on.
  • The fault is tracedMeter readings show whether current is leaking from a cable and whether the cable is unbroken. Together they point to one connection, device or length of cable.
  • The failed part is repaired and tested againOnce the rate and any parts are settled with you, we mend or swap the failed part. Every circuit is tested again before it is switched back on.
  • A note of the work is left with youNotifiable repairs come with NICEIC paperwork. Smaller jobs come with a short written note naming the cause, the parts fitted and the readings taken.

What does it cost to find and fix a power loss?

Tracing a power loss is charged by the hour, so the total follows how long the fault takes to find and what has to be replaced. The first hour pays for attending, testing and beginning the repair.

From £105 an hour

Included

  • Attendance after hours at the Eastleigh, Chandler's Ford, Hedge End, Botley, Whiteley, Segensworth or Southampton address you give
  • Finding the failed circuit, board, plant feed or lighting run
  • Making the installation safe and completing a first repair where parts and time allow
  • A verbal account of what failed and what still needs a return visit
  • NICEIC paperwork only where the work we complete on the night requires it

Not included

  • Full rewires, shop fit outs, new three phase installs and other planned works
  • PAT testing, scheduled fixed wire testing and emergency lighting certificates booked in hours
  • Gas, plumbing, IT software faults and non electrical plant repairs
  • You get the hourly rate in writing before we touch the board, and parts are added on top of the labour.
  • Out of hours emergency callout runs at its own hourly rate, which we give you before we set off.
  • Nothing is charged to quote, to move a booking or to attend.
  • Fixed wire testing is priced on the number of boards and circuits, not by the hour.
  • Emergency lighting is priced per light, and the three hour test is priced separately.
  • Repairs are priced item by item off the report, so you choose what to do and when.
  • Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
  • Quotes are free, rescheduling is free, and there is no callout fee.

Emergency electrician near you

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose MCI Electrical

Photo of David McInnesDavid McInnesElectrician
Trading since
2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”

David McInnes, MCI Electrical

Book Now

Questions about half the house losing power

Still have a question?

Is half a house without power an emergency?

Not on its own. A switch that will not stay up, a burning smell or a wet board is urgent, so keep that circuit off and call. Calls are answered at any time.

How many times can I reset a tripped switch?

Once. A switch that drops again is doing its job by shutting a fault off, so leave it down and call us rather than trying again.

Do I need a new board if half the house trips?

Not necessarily. Testing shows whether the fault sits in the board, a circuit or an appliance. A new board is quoted as its own job only if the results call for one.

Are you NICEIC registered?

Yes. MCI Electrical is NICEIC registered, so any repair that needs a certificate gets one from us when the work is finished.