No power in the whole house

MCI Electrical finds out why a whole property has lost power, makes the installation safe and tells you in plain words what failed, for offices, shops, units and depots.

Calls answered 24/7

  • 17 years trading
  • Local to Eastleigh

Why has the whole house lost power?

A total loss of power has a short list of causes, and which one applies decides whether the fix sits inside your building or out in the street.

  • A power cut on the networkIf neighbouring buildings and the street lights are dark too, the network has lost supply and the fault sits with the distributor. Your own wiring is fine and power returns when they restore it.
  • The main switch or an RCD has trippedThe main switch isolates the whole installation, and an RCD is the device that cuts power when current leaks to earth. Either one dropping takes every circuit off together.
  • A fault on the incoming supplyMeter tails are the short heavy cables between the meter and the consumer unit. Burnt tails or a blown supply fuse leave the whole property dead and need the distributor or an electrician on site.
  • A failed consumer unit or loose connectionA loose or overheated terminal, or a failed main switch, drops the supply inside the building. A burning smell, scorch marks or a hot, buzzing unit point to this.
  • One faulty circuit tripping everythingA failing appliance or a damaged cable can trip the main protection ahead of its own breaker, so every circuit goes dead until the faulty one is found and isolated.

What can I check safely when the power is off?

These checks need no tools and no covers removed. Stop at any sign of burning, water or damage and ring us.

  • Look outside firstSee whether neighbours and street lights have power. If they are dark too, ring 105, the free power cut line for the network. Nothing in your wiring has failed.
  • Read the consumer unitOpen only the door of the unit, never the inner cover. Note whether the main switch or an RCD has dropped, then switch it back on once. If it drops again, leave it off.
  • Unplug, then resetUnplug appliances and switch off the lights before you reset. Bring circuits back one at a time, so the one that trips again shows itself.
  • Leave hot or burnt equipment aloneA burning smell, scorch mark, crackle or a unit that is hot to touch means stop. Do not touch the switches. Ring us and keep people clear of the board.

When should I book an electrician for no power?

Book when the cause is not outside your building, or when anything about the board looks or smells wrong.

  • The switch will not stay onA main switch or RCD that drops again straight after a reset means a fault is live somewhere in the installation. Leave it off and book the fault to be found.
  • Neighbours have power and you do notWith the street lit and your building dark, the problem is on your side of the meter, so it needs testing by an electrician.
  • There is heat, a smell or scorch marksBurnt or hot equipment at the board is a fire risk. Book Now puts you through, and calls are answered at any time.

What happens when we attend a total power loss?

We work from the supply inwards, one stage at a time, so you can see where the fault stops being a mystery.

  • Making it safeWe meet whoever is on site, confirm what failed and isolate anything unsafe, checking the consumer unit and tails for heat damage before anything is switched on.
  • Testing from the supply inwardsWe check voltage at the incoming supply, then the main switch and board, then circuit by circuit until we find exactly where power stops.
  • Repairing the faultWe replace the failed device or remake the connection where parts and time on site allow. Upgrades beyond the fault wait for a separate written quote.
  • Telling you what comes nextBefore we go we say what failed, what is now safe and whether a certificate is due for the work we completed.

What does fixing a total power loss cost?

The price follows the fault we find, because a tripped device and a failed consumer unit are very different jobs. Emergency callout work is charged by the hour, and the first visit covers diagnosing the fault and the first safe repair we can complete.

From £105 an hour

Included

  • Attendance after hours at the Eastleigh, Chandler's Ford, Hedge End, Botley, Whiteley, Segensworth or Southampton address you give
  • Finding the failed circuit, board, plant feed or lighting run
  • Making the installation safe and completing a first repair where parts and time allow
  • A verbal account of what failed and what still needs a return visit
  • NICEIC paperwork only where the work we complete on the night requires it

Not included

  • Full rewires, shop fit outs, new three phase installs and other planned works
  • PAT testing, scheduled fixed wire testing and emergency lighting certificates booked in hours
  • Gas, plumbing, IT software faults and non electrical plant repairs
  • Parts and any further hours are added only once the cause is known, and we tell you before they start.
  • A new consumer unit or repair to the supply cables is a separate job with its own written price.
  • Attendance at night or at weekends carries a different hourly rate, which we state before we leave.
  • Fixed wire testing is priced on the number of boards and circuits, not by the hour.
  • Emergency lighting is priced per light, and the three hour test is priced separately.
  • Repairs are priced item by item off the report, so you choose what to do and when.
  • Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
  • Quotes are free, rescheduling is free, and there is no callout fee.

Emergency electrician near you

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose MCI Electrical

Photo of David McInnesDavid McInnesElectrician
Trading since
2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”

David McInnes, MCI Electrical

Book Now

Questions about a whole property with no power

Still have a question?

Why has all the power gone off at once?

Everything going dead together means the problem sits at the top of the installation: the main switch, an RCD, the consumer unit or the supply coming in. A single faulty circuit rarely takes down the whole property.

Is it a power cut or a fault in my building?

Look at neighbouring buildings and street lights. If they are dark, it is a network power cut and 105 is the number to ring. If they are lit and you are dark, the fault is on your side of the meter.

Can I keep resetting the trip switch?

No. Reset it once with appliances unplugged. If it drops again, a fault is still live, and repeated resetting can overheat the unit. Leave it off and call us.

Do you attend workplaces that lose power out of hours?

We take emergency callouts when a workplace loses power or lighting after hours and cannot wait for the next working day. Calls are answered at any time, and the out of hours rate is stated before we leave.

Are you NICEIC registered?

MCI Electrical is on the NICEIC register. Where the work we complete needs a certificate, we issue it once the job is finished and you keep the paperwork.

Related problems

Sources

Updated 20 November 2026

Book or ask a question

Calls answered 24/7