Why does power keep cutting out?
MCI Electrical finds why power keeps cutting out by testing each circuit from the distribution board outwards, then repairs the loose joint, failing device or overloaded circuit behind it.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why does power keep cutting out?
Power that drops and returns usually means a protective device is reacting to a fault that only shows under certain conditions, such as heavy load, damp or heat.
- A loose connectionA terminal that has worked slack at a socket, switch or the board makes and breaks contact. It heats under load, so the supply fails at busy moments, and a hot joint can arc.
- An overloaded circuitHeaters, machines and chargers sharing one circuit trip its breaker when they run together. The breaker is doing its job, and the answer is to split the load, not to fit a bigger breaker.
- Equipment leaking currentA failing appliance leaks a small current to earth and trips the RCD, the residual current device that cuts power within milliseconds. Unplugging items one at a time shows whether the kit or the wiring is to blame.
- Damaged cable insulationInsulation that has aged, been nipped by a fixing or soaked by damp lets current leak to earth now and then, often after rain or once the cable warms up.
- A tired breaker or RCDA protective device that has worn can trip below its rating. Testing shows whether it is the cause before anyone pays to replace it.
What can I check safely before booking?
Looking, noting and unplugging are safe. Never open a socket, a fitting, the board or an appliance, and treat a warm outlet or a burning smell as urgent.
- Keep a log of the cutsWrite down the time of each cut and what was running. A pattern, such as every morning when the heating starts, tells us which circuit to test first.
- Note which switch droppedOpen the board door and look. Does the same breaker or the RCD drop each time? Take no covers off, and write down which switch it was.
- Reset one time onlySwitch it back on once. If it drops again, leave it off, because every further reset puts power onto a fault that may be heating a joint.
- Ask the neighbouring unitsIf other units lose power at the same moment, the fault sits on the network and the distribution network operator for the area deals with it.
When should I book an electrician?
Book once the cuts repeat, because an intermittent fault tends to worsen rather than clear up. Calls are answered at any time, so you can report it as it happens.
- The same switch trips againBook when a breaker or RCD drops out after one reset. Something on that circuit is leaking or overloaded, and testing finds which.
- The gaps are getting shorterBook when cuts come closer together. A loose joint or damaged cable gets worse with every cycle of heating and cooling.
- There are signs of heatSwitch the circuit off if you can do so safely when a socket feels warm, a fitting smells of burning or a cover has brown marks. Then press Book Now and say what you found.
What happens on the visit?
The visit works through the installation circuit by circuit, starting with the one that cuts out.
- We hear the patternYou tell us when the power drops and what was running. We use that to decide which circuit to test first.
- We isolate and testWe switch the circuit off at the board, then check insulation resistance for leakage, continuity for breaks and the RCD for its trip time. Other circuits stay on where the board layout allows.
- We repair the faultOnce the rate and any parts are confirmed, we remake the loose connection or replace the damaged part, then retest the circuit before it goes back on.
- We leave a recordA notifiable repair comes with NICEIC paperwork. For anything smaller we leave a short note naming the cause, the parts fitted and the readings.
What affects the cost of finding the fault?
Finding an intermittent fault is charged by the hour, and the rate is given in writing before a board is opened. How long the tracing takes and which parts have failed decide the final total.
From £75 an hour
Included
- Attendance at the workplace and a talk through the symptoms with whoever is on site
- Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
- Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
- A written note of the cause, the work done and any further parts still needed
- NICEIC documentation where the repair is notifiable
Not included
- A full fixed wire inspection of every circuit on the premises
- Rewiring a whole board or installing a new three phase supply as part of the same hour
- IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
- A fault that only appears under load can need extra time with the equipment running, which adds hours.
- Replacement breakers, sockets and RCDs are added to the labour, and bigger work the testing uncovers, such as a new board, gets a separate quote.
- Nothing is charged for a quote or for moving the booking, and there is no callout fee. Time beyond normal working hours carries a different rate that you hear first.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowIs it safe to keep resetting the trip switch?
Once is reasonable, to learn whether it was a single event. If it drops again, leave it off and book, because each reset puts power back onto a fault that may be heating a joint.
Will you find the cause if the power stays on during the visit?
Insulation and RCD readings can show leakage while everything is live. If the readings come back clean, we tell you what to note down when the next cut happens.
Could my electricity supplier be causing it?
If neighbouring premises lose power too, the fault lies with the network operator. If only your board trips, the fault is inside your installation and we test it.
Are you NICEIC registered?
Yes, MCI Electrical is NICEIC registered, and a notifiable repair comes with the matching paperwork.
Related problems
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Fuse keeps blowingRepeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- Lights not working but sockets are fineSockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- MCB keeps tripping in a commercial buildingA tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.