Why does my RCD keep tripping at work?
An RCD keeps tripping when current is leaking to earth somewhere on its circuits, and MCI Electrical tests each circuit to find the faulty item and repair it for businesses in Eastleigh.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why does an RCD keep tripping?
An RCD is a switch that cuts power the moment current leaks to earth, so a repeat trip means something on its circuits is leaking.
- An appliance is leaking currentKettles, urns, heaters and dishwashers can leak as their insulation wears. The RCD trips when that item is switched on and stays on when it is unplugged.
- Damp has reached a connectionWater in an outside light, a socket in a wash area or a junction box that collects condensation lets current escape. Trips often follow rain or a wash down.
- A cable has been damagedA cable that has been nicked, crushed under trunking or drilled into leaks current to earth at the point of damage, and the trip can come and go.
- Too many items share one RCDComputers, chargers and fittings each leak a tiny amount. On one RCD those amounts add up, and together they can trip a device that coped with each one alone.
- The RCD itself has wornAn ageing RCD can trip at a lower leakage than it should, or refuse to reset. Testing shows whether the device or the circuit behind it is at fault.
What can I check myself when the RCD keeps tripping?
You can note what tripped, unplug items and reset once without opening anything. Leave covers, wiring and fixed equipment alone.
- Note what was runningWrite down what was switched on when it tripped, and whether lights, sockets or the cooker went off with it. That points to the circuit involved.
- Unplug and reset onceTake the plugs out on the dead circuit, press the RCD back on one time, then reconnect items separately. An item that trips it again stays unplugged and gets reported.
- Press the test buttonThe test button on the RCD should make it trip. If it will not trip, or will not switch back on, leave it off and report that.
- Stop when it trips againIf it trips straight away with everything unplugged, leave it off. Never hold the switch up or tape it, and keep every cover closed.
When should I book an electrician for a tripping RCD?
Book once one reset and unplugging have not cured it, or at once if there are signs of heat or water.
- It will not stay onAn RCD that trips again after one reset has found a real leak. Repeated resets push current through the fault and can overheat the connection.
- It trips when a machine startsA trip that follows one machine, extractor fan or heater points to that item or its supply, and testing separates the two.
- You see heat or damp, or smell burningScorch marks, a warm board or water near a fitting need attention straight away. Switch off what you can safely reach and Book Now. Call 999 if there is smoke or flame.
What happens when an electrician comes to a tripping RCD?
The visit follows the leak from the RCD out along each circuit until it is found and mended.
- We ask what trips it and whenWe ask what was running, how often it trips and what you have tried. The affected circuit is isolated at the board before anything is opened.
- We test each circuitEvery circuit on the RCD is tested for leakage one at a time, with items unplugged. That separates a faulty appliance from damage in the fixed wiring.
- We repair the causeWe replace the damaged accessory, connection or device where the parts allow, and explain what else is needed if they do not.
- We retest and leave a noteThe circuit is tested again before the RCD goes back on. You see it working and receive a written note of the cause and the work done.
How is RCD fault finding priced?
Fault finding is charged by the hour, so the total depends on how many circuits sit behind the RCD and how long the leak takes to find. The rate covers attending, testing and the repair, with parts on top.
From £75 an hour
Included
- Attendance at the workplace and a talk through the symptoms with whoever is on site
- Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
- Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
- A written note of the cause, the work done and any further parts still needed
- NICEIC documentation where the repair is notifiable
Not included
- A full fixed wire inspection of every circuit on the premises
- Rewiring a whole board or installing a new three phase supply as part of the same hour
- IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
- Quotes are free, a visit can be rescheduled free of charge, and there is no callout fee.
- Parts and extra time are shown to you before they are fitted or worked.
- Work after your normal hours has a different rate, and you hear it before we set off.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowCan one appliance trip the RCD for the whole workplace?
Yes. A faulty urn, dishwasher or heater can leak enough current to trip an RCD that covers several circuits, which switches off everything else on it too. Unplugging items one by one shows which is to blame.
Is it safe to keep resetting the RCD?
No. One reset after unplugging is reasonable. If it trips again, leave it off, because each reset pushes current through the fault.
Can you repair the fault on the same visit?
When the faulty part is small, such as a socket or a connection, we can change it on the visit if the part is to hand. A bigger fault, such as damaged cable, is explained and priced first.
Why does the RCD only trip when it rains?
Rain and damp get into outside lights, external sockets and junction boxes, and the water lets current leak to earth. Testing finds which fitting is letting the water in.
Related problems
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Fuse keeps blowingRepeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- Lights not working but sockets are fineSockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- MCB keeps tripping in a commercial buildingA tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
Sources
- HSE: electrical faults, RCDs and competence
- BS 7671: IET Wiring Regulations (18th Edition, Amendment 2)
- HSE: Electrical Safety at Work
Updated 20 November 2026