Why an RCD trips at night
An RCD that trips at night is usually reacting to something that switches on after closing, such as a timed heater or a freezer, and MCI Electrical tests the circuits to find which one carries the fault.
Calls answered 24/7
- 17 years trading
- Local to Eastleigh
Why does an RCD trip only at night?
Few loads run overnight and most of them sit on timers, so the clock time of the trip is the first clue to the cause.
- An immersion heater on a timer or Economy 7Economy 7 is a cheap overnight electricity tariff, and water heaters on it come on at the changeover. An element with worn insulation leaks current to earth as soon as it heats.
- A fridge or freezer compressor startingA compressor cycles on and off through the night. A motor with a developing earth fault trips the RCD when it starts, and nobody is awake to see which unit did it.
- Heating or a dehumidifier on a timerBoilers, electric heaters and dehumidifiers on a timer start together at set times. Any one that leaks to earth takes the circuit down the moment it switches on.
- Damp in outdoor fittings and socketsAs the air cools, condensation settles in external lights, sockets and junction boxes. Moisture gives current a path to earth, which is why these trips land in the small hours.
What can I check safely when it trips at night?
These checks involve only a clock, a plug and the timer settings, so nothing is opened and no wiring is touched.
- Note the time of each tripWrite down when the RCD trips, reading it from a clock that has stopped or reset. A trip at the same minute every night points to a timer.
- Compare it with timers and the tariffLook at the time settings on heating, water heaters and the Economy 7 changeover, and see whether any of them match the time you noted.
- Unplug one timed item each nightUnplug a portable timed item such as a dehumidifier or heater, one per night, and reset the RCD once. If the trips stop, leave that item unplugged and tell us which one it was.
When should I book an electrician for night trips?
Book as soon as a pattern shows. Book Now takes the details at any hour, because our assistant answers calls day and night.
- The trips repeat every nightA trip every night means a fault shows itself each time something switches on, and unplugging timed items has not removed it.
- Overnight equipment depends on that circuitFreezers, alarms, security systems and monitoring equipment lose power when the RCD drops, so book rather than wait for the next trip.
- There is heat, damage or a burning smellLeave the RCD off, do not reset it again and call straight away.
What happens when you attend an RCD that trips at night?
We start from the trip times you noted, because they decide which circuits and loads are tested first.
- Going through the trip patternWe ask when it trips, what runs at that time and what you have already unplugged. That narrows the list of circuits before any testing starts.
- Isolating and testing circuitsWe switch off one circuit at a time and test each with insulation resistance readings, which show where current is leaking to earth. Circuits on other ways stay live where the board layout allows.
- Testing the suspect loadImmersion elements, compressors and timed heaters are tested on their own until the leaking one shows up. A fault that comes and goes can have a data logger fitted to record exactly when it trips.
- Repairing and leaving a noteOnce the cause is found we repair it and test the circuit again. You keep a short written note of the cause, the parts used and the test readings.
How is RCD fault finding priced?
Fault finding is charged by the hour, and the hours cover attending, testing the circuits and doing the repair. Trips that are hard to catch can take longer, which adds hours.
From £75 an hour
Included
- Attendance at the workplace and a talk through the symptoms with whoever is on site
- Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
- Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
- A written note of the cause, the work done and any further parts still needed
- NICEIC documentation where the repair is notifiable
Not included
- A full fixed wire inspection of every circuit on the premises
- Rewiring a whole board or installing a new three phase supply as part of the same hour
- IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
- There is no callout fee, and quotes and rescheduling cost nothing.
- Emergency callouts carry their own hourly rate, and we tell you what it is before we set off.
- A part found faulty, such as an element or a protective device, is added to the bill after the testing.
- Fixed wire testing is priced on the number of boards and circuits, not by the hour.
- Emergency lighting is priced per light, and the three hour test is priced separately.
- Repairs are priced item by item off the report, so you choose what to do and when.
- Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
- Quotes are free, rescheduling is free, and there is no callout fee.
Electrical fault finding near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose MCI Electrical
- Trading since
- 2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”
David McInnes, MCI Electrical
Book NowWhy does my RCD only trip at night?
Something is switching on overnight. Timed heaters, immersion elements, compressors and damp outdoor fittings are the usual suspects, and the time of the trip tells us which to test first.
Can an outdoor light or socket trip the RCD at night?
Yes. Condensation settles in outdoor fittings as the air cools and lets current leak to earth. Testing the circuit shows whether a fitting is wet or failing.
Could the Economy 7 changeover cause it?
Yes, when a water heater or storage heater switches on at the changeover with a leak to earth. We test the heater and its circuit, and your energy supplier deals with the meter itself.
Will my freezer lose power when the RCD trips?
Yes, if it shares the circuit that trips. Everything on that circuit stays off until the RCD is reset, so book soon if the freezer matters to you.
How do you catch a trip that comes and goes?
We fit a data logger to the circuit. It records when the trip happens, so a fault that only appears while nobody is watching still gets caught and tested.
Related problems
- Circuit breaker keeps trippingA breaker that keeps tripping is either overloaded or protecting against a fault, and testing the circuit shows which.
- Consumer unit tripping with nothing plugged inA trip with nothing plugged in points to fixed wiring, lighting or wired in equipment, which needs testing one circuit at a time.
- Cooker switch not workingPower to a cooker passes through a breaker, a wall switch and the appliance's own terminals, and a reading at each one shows where it stops.
- Fuse keeps blowingRepeated blown fuses mean too much current, from an overload or a fault, and a test of the circuit shows which one.
- Lights not working but sockets are fineSockets work because they run on separate circuits, so the fault is on the one lighting circuit that has stopped.
- MCB keeps tripping in a commercial buildingA tripping MCB means its circuit is overloaded or has a fault, and testing outwards from the board shows which one and what has to change.
Sources
- Electrical Safety First: Safety Guidance
- NICEIC: Householder Guidance
- BS 7671: IET Wiring Regulations (18th Edition)
Updated 20 November 2026