RCD tripping when it rains

An RCD trips in the rain when water gives current a path to earth at an outside socket, light, joint or cable. MCI Electrical tests the circuit to find that fault at commercial premises in Eastleigh.

Calls answered 24/7

  • 17 years trading
  • Local to Eastleigh

Why does my RCD trip when it rains?

An RCD is the safety switch that cuts the supply when current escapes from where it should run. Rain finds the weak point in an outdoor circuit.

  • Car park and building lightsWall lights, bollards and flood lights let rain past a split gasket or a loose cable entry. The wet fitting leaks to earth and the RCD switches the whole lighting circuit off.
  • Yard and loading bay socketsSockets used for tools, pressure washers and vehicle chargers collect water behind lids that no longer close. Wet pins and terminals trip the RCD, often with a plug in item connected.
  • Cable joints and glandsA cable gland is the seal where a cable enters a box or machine. Where one has perished, or a joint was never made watertight, rain creeps along the cable to the live conductors.
  • Roof and external plantExtractor fans, air conditioning units, signs and shutter motors sit in the weather. Rain reaching their terminals or motor windings trips the RCD that protects their supply.
  • A worn RCDAn ageing RCD can trip in damp air while the circuit behind it tests clear. Checking the device and the cables separately shows which of the two has failed.

What can I safely check when my RCD trips in the rain?

Look and make notes only. Leave covers on, leave wet fittings alone and never touch wiring or the inside of the board.

  • Note when it tripsWrite down whether it trips during the rain, after it, or only when one outside light or machine is switched on. That pattern points towards the faulty circuit.
  • Unplug outside itemsPull plugs from yard sockets, including tools, chargers and extension leads, if you can reach them dry. Then reset the RCD once. If it trips again, leave it off.
  • Look from a distanceLook at outside lights, sockets and plant for cracked covers, open lids, dripping water or scorch marks. Keep your hands off anything wet.
  • Note what lost powerList the rooms, tills, lights and machines that went dead. That shows which circuits sit behind the RCD that tripped.

When should I book an electrician for an RCD that trips in the rain?

Book Now if the RCD trips a second time, or if anything outside is wet, damaged or warm to the touch.

  • It trips again after one resetA second trip means the leak is still there. Leave the RCD off and the affected circuit unused until it has been tested.
  • Water or damage at a fittingWater inside a light, socket or enclosure, a cracked cover or a pulled cable needs testing before anyone uses that circuit again.
  • Heat, a buzz or a burning smellA warm board, humming or a burnt smell can mean a loose connection that is arcing. Stop resetting, leave it off and book.
  • Trading depends on that circuitTills, chillers, alarms and machines stop when their circuit goes off. A visit traces the leak so the circuit is not reset day after day.

What happens on a visit for an RCD that trips in the rain?

We start at the board with whoever knows the premises, then follow the tripped circuit outwards until the leak has a named cause.

  • Find the tripped circuitWe note which RCD or breaker has operated and what lost power, then switch that circuit off and prove it dead before any cover comes off.
  • Test the cable and fittingsAn insulation resistance test measures leakage between the conductors and earth with the supply off. We repeat it along the circuit to narrow down the light, socket, joint or plant at fault.
  • Repair the failed partWe replace or reseal the part that failed, such as a gasket, gland, socket or joint, once you say go ahead. Other circuits stay live where the board layout allows.
  • Test again and record itWe test the circuit once more and leave a written note of the cause, the parts used and the readings. NICEIC paperwork follows where the repair is notifiable.

What does tracing an RCD trip cost and what changes it?

The hourly rate for commercial fault finding covers attendance, testing and the repair time needed to trace why the RCD trips. The total moves with how long the leak takes to find, the parts it needs and the hours the work is done in.

From £75 an hour

Included

  • Attendance at the workplace and a talk through the symptoms with whoever is on site
  • Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
  • Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
  • A written note of the cause, the work done and any further parts still needed
  • NICEIC documentation where the repair is notifiable

Not included

  • A full fixed wire inspection of every circuit on the premises
  • Rewiring a whole board or installing a new three phase supply as part of the same hour
  • IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
  • A single wet light takes less time than a leak somewhere along a long outdoor cable.
  • Replacing a failed RCD or distribution board is priced as separate work, apart from the hours spent finding the fault.
  • An emergency callout carries its own hourly rate, which we tell you before we set off.
  • Fixed wire testing is priced on the number of boards and circuits, not by the hour.
  • Emergency lighting is priced per light, and the three hour test is priced separately.
  • Repairs are priced item by item off the report, so you choose what to do and when.
  • Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
  • Quotes are free, rescheduling is free, and there is no callout fee.

Electrical fault finding near you

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose MCI Electrical

Photo of David McInnesDavid McInnesElectrician
Trading since
2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”

David McInnes, MCI Electrical

Book Now

Your questions about RCDs tripping in wet weather

Still have a question?

Why does my RCD only trip when it is raining?

Water finds a weak seal, a cracked cover or damaged cable and lets a small current escape to earth. The RCD senses the escape and cuts the supply. When the weather dries the leak stops, which is why the fault seems to come and go.

Is it safe to keep resetting the RCD?

No. Reset it once at most, with outside plugs removed. If it trips again the leak is still there, so leave it off and have the circuit tested.

Will the rest of the building lose power while you work?

That depends on how the board is split. Where the affected circuit has its own way we switch off only that one, and the rest of the building carries on.

Can you repair the fault on the same visit?

Where the failed part is a seal, socket, joint or fitting, we can repair it once you say go ahead. A new cable or a new board is a larger job, so it is quoted separately first.