Trip switch keeps going off for no clear reason

A trip switch that keeps going off at random usually means a fault that only shows under certain loads or conditions. MCI Electrical tests the circuits at your Eastleigh premises to find it.

Calls answered 24/7

  • 17 years trading
  • Local to Eastleigh

Why does a trip switch keep going off at random?

Random tripping means the protection keeps meeting a fault that comes and goes. Heat, damp, vibration and the load on the circuit decide when it shows.

  • A loose connectionA terminal that has worked loose can hold while cold, then arc as it warms and expands. The switch drops when the joint heats up and holds again once it cools.
  • Small leaks that add upEvery appliance leaks a tiny amount to earth. Kettles, chillers, heaters and chargers on one RCD, the residual current device that watches for leakage, add together until the total crosses its limit.
  • Worn cable insulationInsulation that has cracked or rubbed through leaks current only when the cable moves, warms or turns damp. Cables beside heaters, doors and plant wear fastest.
  • Equipment that fails part way through its cycleA compressor, heater or pump can leak or overload during one stage of its cycle only. The trips then look random, although they follow that stage.
  • A breaker that is wearing outA breaker or RCD that has dropped many times can lose accuracy and open at a lower current than it should. Testing shows whether the device still works as it was built to.

What can I check safely when a trip switch keeps going off?

Look, listen and write things down. Never open a board, socket or appliance, and never hold a switch up.

  • Keep a trip logNote the date, time, which switch dropped and what was running. Add the weather and whether heating or air conditioning had just started. A pattern points us to the circuit.
  • Note which kind of switch droppedA small breaker points to an overload or a fault on one circuit. An RCD points to leakage somewhere on the circuits it covers. Write down which one it was each time.
  • Unplug the likely itemIf the trips follow a pattern, unplug the equipment that seems linked and see whether the switch holds. Reset a dropped switch once only, and leave it down if it will not stay up.
  • Look and smell near the boardCheck for warmth, buzzing, a burning smell or damp around the board and the dead fittings. If you find any, leave that switch down and book.

When should I book an electrician for a trip switch that keeps going off?

Book Now once the trips repeat. An intermittent fault rarely clears by itself and can turn into a permanent one without warning.

  • The trips keep coming backA switch that drops again after a reset, or every few days, means something is still wrong. The longer it runs, the harder the fault is to catch in the act.
  • Heat, a smell or cracklingA warm board, a burning smell or crackling can mean a joint that is arcing, which is a fire risk. Leave the circuit off and book at once.
  • Essential equipment goes downTills, alarms, chillers and emergency lighting stop when their switch drops. Tell us what sits on that circuit so the visit is planned around it.
  • It happens after hoursCalls are answered at any hour. Work at night or at weekends carries a different rate, and we state it before we set off.

What happens on a visit for a trip switch that keeps going off?

We start at the board with your log, then test each circuit with the power off to find what the switch keeps reacting to.

  • Read the log at the boardWe go through the log with whoever is on site and match the trips to circuits and equipment. The board cover stays on until a test meter confirms the circuit is dead.
  • Test the circuit that trippedAn insulation resistance test measures current leaking between the conductors and earth, and a continuity test follows the cable. We also check that the RCD opens at the leakage it should.
  • Separate the equipment from the wiringWe repeat the tests with the suspect appliance unplugged. That shows whether the fault sits in the equipment or in the fixed wiring.
  • Repair, test again and hand overThe repair goes ahead once you accept the price, and we test the circuit again afterwards. NICEIC paperwork follows where the work needs it. If the fault stays quiet that day, we tell you which circuit to watch.

How is a random tripping fault priced?

Fault finding is charged by the hour, and that time covers attendance, testing and the first repair. A fault that shows itself now and then takes longer to catch than one that trips at once, and awkward access to the board adds time.

From £75 an hour

Included

  • Attendance at the workplace and a talk through the symptoms with whoever is on site
  • Safe isolation, testing and tracing from the distribution board to the failed outlet, light or machine feed
  • Repair of the defective connection, device or cable where the materials are available on the van or from a local merchant
  • A written note of the cause, the work done and any further parts still needed
  • NICEIC documentation where the repair is notifiable

Not included

  • A full fixed wire inspection of every circuit on the premises
  • Rewiring a whole board or installing a new three phase supply as part of the same hour
  • IT hardware repair, software faults or telecoms work beyond the electrical supply to the cabinet
  • Time on site varies with how quickly the fault shows itself, so the total depends on the fault and not on the equipment alone.
  • Replacement parts and any later repair are priced once testing has named the cause.
  • There is no callout fee, and after hours work carries its own rate that we give before we set off.
  • Fixed wire testing is priced on the number of boards and circuits, not by the hour.
  • Emergency lighting is priced per light, and the three hour test is priced separately.
  • Repairs are priced item by item off the report, so you choose what to do and when.
  • Work outside your trading hours costs a different rate, and I tell you what it is before I set off.
  • Quotes are free, rescheduling is free, and there is no callout fee.

Electrical fault finding near you

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose MCI Electrical

Photo of David McInnesDavid McInnesElectrician
Trading since
2009
“I have worked on commercial premises across Eastleigh and Southampton since 2009. I quote the job, do the work and sign it off myself, so you always deal with the person who knows your building.”

David McInnes, MCI Electrical

Book Now

Questions about a trip switch that keeps going off

Still have a question?

Can I keep resetting the switch until it stays up?

No. Resetting again and again hides the fault and can overheat a loose joint. Reset once, and if it drops again leave it off until the circuit has been tested.

Is a switch that only drops now and then an emergency?

Not usually, but an intermittent fault can become permanent without warning. Heat, a burning smell or damp is different: leave the switch off and book straight away.

Could the trip switch itself be faulty?

Yes. Breakers and RCDs wear, especially after many trips. We test the device against the circuit it protects to show which of the two has failed.

What should I tell you before the visit?

Tell us which switch drops, how often, what was running and what lost power. A log with dates and times helps most, because it tells us where to start testing.